Εμφάνιση απλής εγγραφής

dc.contributor.author Σγουρός, Νικόλαος el
dc.contributor.author Αθηναίος, Σπύρος el
dc.contributor.author Σαγκριώτης, Μανώλης el
dc.contributor.author Παπαγέωργας, Παναγιώτης Γ. el
dc.contributor.author Θεοφάνους, Νικηφόρος el
dc.date.accessioned 2015-05-11T15:24:47Z
dc.date.available 2015-05-11T15:24:47Z
dc.date.issued 2015-05-11
dc.identifier.uri http://hdl.handle.net/11400/10145
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source https://www.osapublishing.org en
dc.source https://www.osapublishing.org/oe/fulltext.cfm?uri=oe-14-22-10403&id=116551 en
dc.subject Φωτογραφία
dc.subject Φακοί
dc.subject Τρισδιάστατη απεικόνιση
dc.subject Three-dimensional imaging
dc.subject Photography
dc.subject Optics
dc.title Accurate lattice extraction in integral images en
heal.type journalArticle
heal.classification Technology
heal.classification Electronics
heal.classification Τεχνολογία
heal.classification Ηλεκτρονική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85133147
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85042383
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Ηλεκτρονική
heal.identifier.secondary DOI: 10.1364/OE.14.010403
heal.language en
heal.access free
heal.publicationDate 2006-10
heal.bibliographicCitation Sgouros, N., Athinaios, S., Sangriotis, M., Papageorgas, P. and Theofanous, N. (2006) Accurate lattice extraction in integral images. "Optics Express", 14 (22), p.10403-10409 en
heal.abstract Integral imaging is one of the most promising techniques for delivering three-dimensional content. Most processing tasks usually require prior knowledge of the size and positions of the elemental images that comprise an integral image. In this paper we propose an automated method for calibrating the acquisition setup, by applying a preprocessing stage to an acquired integral image. The skew angle is extracted and the size and positions of the elemental images are accurately determined. For these purposes a method is developed to automatically identify an elemental image lattice that best matches the acquired integral image. en
heal.publisher Optical Society of America en
heal.journalName Optics Express en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες