Εμφάνιση απλής εγγραφής

dc.contributor.author Νίνος, Κωνσταντίνος Δ. el
dc.contributor.author Κωστόπουλος, Σπυρίδων el
dc.contributor.author Γκλώτσος, Δημήτριος el
dc.contributor.author Γεωργιάδης, Παντελής el
dc.contributor.author Σιδηρόπουλος, Κωνσταντίνος el
dc.date.accessioned 2015-05-14T11:37:26Z
dc.date.issued 2015-05-14
dc.identifier.uri http://hdl.handle.net/11400/10359
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://jtt.sagepub.com/content/16/5/232.short en
dc.subject Personal digital assistant
dc.subject Teleradiology
dc.subject Προσωπικός ψηφιακός βοηθός
dc.subject Τηλεακτινολογίας
dc.title Development and evaluation of a PDA-based teleradiology terminal in thyroid nodule diagnosis en
heal.type journalArticle
heal.classification Technology
heal.classification Biomedical engineering
heal.classification Τεχνολογία
heal.classification Βιοϊατρική τεχνολογία
heal.classificationURI http://zbw.eu/stw/descriptor/10470-6
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85014237
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Βιοϊατρική τεχνολογία
heal.contributorName Δημητρόπουλος, Νικόλαος el
heal.contributorName Καλατζής, Ιωάννης el
heal.contributorName Κάβουρας, Διονύσης Α. el
heal.identifier.secondary doi: 10.1258/jtt.2010.090512
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2010
heal.bibliographicCitation Ninos, K., Kostopoulos, S., Glotsos, D., Georgiadis, P., Sidiropoulos, K., et al. (July 2010). Development and evaluation of a PDA-based teleradiology terminal in thyroid nodule diagnosis. Journal of Telemedicine and Telecare. 16(5). pp. 232–236. SAGE Publications: 2010. en
heal.abstract We developed a wireless personal digital assistant (PDA)-based teleradiology terminal which allowed a secure connection to the hospital's Picture Archiving and Communication System (PACS) through the DICOM protocol. Ten members of the hospital's medical staff completed a questionnaire about its mobility, usability, stability, performance and diagnostic efficiency in a real health-care environment. There was a high degree of satisfaction with the system's mobility (mean score 4.1, SD 1.0, on a five-point scale), usability (mean score 4.2, SD 1.1), stability (mean score 3.9, SD 0.4) and performance (mean score 4.2, SD 0.6). The system was evaluated as a tool for providing assistance in diagnosing thyroid nodules from ultrasound images. A total of 144 ultrasound images with thyroid nodules were assessed by an expert. Six image quality attributes were evaluated. The physician concluded that the ultrasound thyroid images on the PDA screen were of similar quality to those displayed on a diagnostic visual display unit screen. However, the expert found difficulties in diagnosing microcalcification, internal echo texture and vascularity. The PDA terminal provided rapid, secure and convenient portable access to PACS images and the image quality was sufficient for diagnostic interpretation of ultrasound images of the thyroid. en
heal.publisher SAGE Publications en
heal.journalName Journal of Telemedicine and Telecare en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Development and evaluation of a ...
    Μέγεθος: 1.305Mb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες