Εμφάνιση απλής εγγραφής

dc.contributor.author Πάτσης, Γεώργιος el
dc.contributor.author Πετρόπουλος, Α. el
dc.contributor.author Καλτσάς, Γ. el
dc.date.accessioned 2015-05-16T17:16:41Z
dc.date.available 2015-05-16T17:16:41Z
dc.date.issued 2015-05-16
dc.identifier.uri http://hdl.handle.net/11400/10543
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com en
dc.source http://www.sciencedirect.com/science/article/pii/S1877705810009069 en
dc.subject Θερμικός αισθητήρας
dc.subject Πλαστικό υπόστρωμα
dc.subject Experiments
dc.subject Πειράματα
dc.title Modelling and evaluation of a thermal microfluidic sensor fabricated on plastic substrate en
heal.type journalArticle
heal.classification Technology
heal.classification Electronics
heal.classification Τεχνολογία
heal.classification Ηλεκτρονική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85133147
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85042383
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Ηλεκτρονική
heal.identifier.secondary DOI: dx.doi.org/10.1016/j.proeng.2010.09.359
heal.language en
heal.access free
heal.publicationDate 2010-10-23
heal.bibliographicCitation Patsis, G., Petropoulos, A. and Kaltsas, G. (2010) Modelling and evaluation of a thermal microfluidic sensor fabricated on plastic substrate. "Procedia Engineering", 5, p.1328–1331 en
heal.abstract Both the simulation and the experimental evaluation of a thermal microfluidic flow sensor are presented in this work. The sensor was evaluated in the calorimetric principle of operation with water as the test liquid. The simulation of the sensor operation was performed into the framework of Comsol® software package. Various combinations of microchannel geometries were tested with different input flow rate values. The operational parameters of the device were simulated by 3D models. The dominant operation parameter was determined to be the distance of the upstream-downstream sensing elements to the heater, the effect of which was theoretically extracted and experimentally verified. en
heal.publisher Elsevier en
heal.journalName Procedia Engineering en
heal.journalType peer-reviewed