Εμφάνιση απλής εγγραφής

dc.contributor.author Πυλαρινός, Διονύσιος el
dc.contributor.author Σιδεράκης, Κυριάκος el
dc.contributor.author Θαλασσινάκης, Εμμανουήλ el
dc.contributor.author Πυργιώτη, Ελευθερία el
dc.contributor.author Βιτέλλας, Ισίδωρος el
dc.date.accessioned 2015-05-24T09:57:00Z
dc.date.available 2015-05-24T09:57:00Z
dc.date.issued 2015-05-24
dc.identifier.uri http://hdl.handle.net/11400/11030
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com/science/article/pii/S0378779611002586 en
dc.subject Data size
dc.subject Waveform
dc.subject Μέγεθος δεδομένων
dc.subject Κυματομορφή
dc.title Online applicable techniques to evaluate field leakage current waveforms en
heal.type journalArticle
heal.classification Technology
heal.classification Biomedical engineering
heal.classification Τεχνολογία
heal.classification Βιοϊατρική τεχνολογία
heal.classificationURI http://zbw.eu/stw/descriptor/10470-6
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85014237
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Βιοϊατρική τεχνολογία
heal.contributorName Δαυίδ, Στράτος Λ. el
heal.identifier.secondary doi:10.1016/j.epsr.2011.10.009
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2012
heal.bibliographicCitation Pylarinos, D., Siderakis, K., Thalassinakis, E., Pyrgioti, E., Vitellas, I., et al. (March 2012). Online applicable techniques to evaluate field leakage current waveforms. Electric Power Systems Research. 84(1). pp. 65-71. Elsevier B.V: 2012. Available from: http://www.sciencedirect.com/science/article/pii/S0378779611002586 [Accessed 09/11/2011] en
heal.abstract Leakage current monitoring is widely employed in order to investigate electrical surface activity and overall performance of high voltage insulators. Both activity and performance are closely linked with local conditions and experienced pollution. Therefore, field measurements are necessary to acquire an exact view of experienced activity and performance. However, field noise and the size of accumulated data are issues of concern in the case of field monitoring. In this paper, 75,887 leakage current waveforms obtained through more than six years of monitoring on 18 post insulators of different material, installed at two different 150 kV substations exposed to marine and industrial pollution, are investigated in order to evaluate the noise and data size problems. Three different types of noise are identified and their impact on raw data as well as their contribution to the data size is evaluated. Three different techniques are proposed to cope with the noise and data size problems. The techniques are selected so as to be online and hardware applicable in order to be incorporated in improved leakage current monitoring systems. Each technique is evaluated individually and in combination with the others. Combined use of all three, is proposed as a prerecording stage, able of coping with both noise and data size problems. en
heal.publisher Elsevier B.V. en
heal.journalName Electric Power Systems Research en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Online applicable techniques to ...
    Μέγεθος: 603.7Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες