dc.contributor.author | Bliznakova, K. | en |
dc.contributor.author | Speller, R. | en |
dc.contributor.author | Horrocks, J. | en |
dc.contributor.author | Λιαπαρίνος, Παναγιώτης Φ. | el |
dc.contributor.author | Κολίτση, Ζ. | el |
dc.date.accessioned | 2015-05-24T17:53:09Z | |
dc.date.available | 2015-05-24T17:53:09Z | |
dc.date.issued | 2015-05-24 | |
dc.identifier.uri | http://hdl.handle.net/11400/11057 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.sciencedirect.com/science/article/pii/S0010482509002121 | en |
dc.subject | X-ray imaging simulation | |
dc.subject | Synchrotron radiation | |
dc.subject | Προσομοίωση απεικόνισης με ακτίνες Χ | |
dc.subject | Ακτινοβολία Synchrotron | |
dc.title | Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Biomedical engineering | |
heal.classification | Ιατρική | |
heal.classification | Βιοϊατρική τεχνολογία | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85014237 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Βιοϊατρική τεχνολογία | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85131615 | |
heal.contributorName | Παλληκαράκης, Νικόλαος | el |
heal.identifier.secondary | doi:10.1016/j.compbiomed.2009.11.017 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2010 | |
heal.bibliographicCitation | Bliznakova, K., Speller, R., Horrocks, J., Liaparinos, P., Kolitsi, Z., et al. (February 2010). Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging. Computers in Biology and Medicine. 40(2). pp. 208-214. Elsevier Ltd: 2010. Available from: http://www.sciencedirect.com/science/article/pii/S0010482509002121 [Accessed 06/01/2010] | en |
heal.abstract | Computer models and simulations of X-ray imaging systems are becoming a very precious tool during the development and evaluation of new X-ray imaging techniques. To provide, however, a faithful simulation of a system, all components must be accurately modelled and tested, followed by verification through experimental measurements. This paper presents a validation study of the XRayImagingSimulator, an in-house developed X-ray imaging simulator, which is extensively used as a basic tool in carrying out complex breast imaging simulations. The approach followed compares results obtained via an experimental setup for breast phantom (CIRS 011A) imaging, using synchrotron radiation (SYRMEP beamline at ELETTRA), with those from its simulated setup under the same conditions. The study demonstrated a very good agreement between experimental and simulated images compared both in terms of subjective and objective criteria. The combination of the XRayImagingSimulator with our BreastSimulator provides a powerful tool for in silico testing of new X-ray breast imaging approaches. | en |
heal.publisher | Elsevier Ltd. | en |
heal.journalName | Computers in Biology and Medicine | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: