Εμφάνιση απλής εγγραφής

dc.contributor.author Bliznakova, K. en
dc.contributor.author Speller, R. en
dc.contributor.author Horrocks, J. en
dc.contributor.author Λιαπαρίνος, Παναγιώτης Φ. el
dc.contributor.author Κολίτση, Ζ. el
dc.date.accessioned 2015-05-24T17:53:09Z
dc.date.available 2015-05-24T17:53:09Z
dc.date.issued 2015-05-24
dc.identifier.uri http://hdl.handle.net/11400/11057
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com/science/article/pii/S0010482509002121 en
dc.subject X-ray imaging simulation
dc.subject Synchrotron radiation
dc.subject Προσομοίωση απεικόνισης με ακτίνες Χ
dc.subject Ακτινοβολία Synchrotron
dc.title Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging en
heal.type journalArticle
heal.classification Medicine
heal.classification Biomedical engineering
heal.classification Ιατρική
heal.classification Βιοϊατρική τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85014237
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Βιοϊατρική τεχνολογία
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85131615
heal.contributorName Παλληκαράκης, Νικόλαος el
heal.identifier.secondary doi:10.1016/j.compbiomed.2009.11.017
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2010
heal.bibliographicCitation Bliznakova, K., Speller, R., Horrocks, J., Liaparinos, P., Kolitsi, Z., et al. (February 2010). Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging. Computers in Biology and Medicine. 40(2). pp. 208-214. Elsevier Ltd: 2010. Available from: http://www.sciencedirect.com/science/article/pii/S0010482509002121 [Accessed 06/01/2010] en
heal.abstract Computer models and simulations of X-ray imaging systems are becoming a very precious tool during the development and evaluation of new X-ray imaging techniques. To provide, however, a faithful simulation of a system, all components must be accurately modelled and tested, followed by verification through experimental measurements. This paper presents a validation study of the XRayImagingSimulator, an in-house developed X-ray imaging simulator, which is extensively used as a basic tool in carrying out complex breast imaging simulations. The approach followed compares results obtained via an experimental setup for breast phantom (CIRS 011A) imaging, using synchrotron radiation (SYRMEP beamline at ELETTRA), with those from its simulated setup under the same conditions. The study demonstrated a very good agreement between experimental and simulated images compared both in terms of subjective and objective criteria. The combination of the XRayImagingSimulator with our BreastSimulator provides a powerful tool for in silico testing of new X-ray breast imaging approaches. en
heal.publisher Elsevier Ltd. en
heal.journalName Computers in Biology and Medicine en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Experimental validation of a ...
    Μέγεθος: 585.5Kb
    Μορφότυπο: PDF