Εμφάνιση απλής εγγραφής

dc.contributor.author Αποστόλου, Θεοφύλακτος el
dc.contributor.author Pascual, Núria en
dc.contributor.author Marco, Maria-Pilar en
dc.contributor.author Μόσχος, Αναστάσιος el
dc.contributor.author Πετρόπουλος, Αναστάσιος el
dc.date.accessioned 2015-05-26T06:19:25Z
dc.date.available 2015-05-26T06:19:25Z
dc.date.issued 2015-05-26
dc.identifier.uri http://hdl.handle.net/11400/11160
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com/ en
dc.subject 2,4,6-trichloroanisole (TCA)
dc.subject Bioelectric Recognition Assay (BERA)
dc.subject Cellular biosensor
dc.subject Cork taint
dc.subject Membrane-engineering
dc.subject 2,4,6-Τριχλωροανισόλη
dc.subject Κινητός βιοαισθητήρας
dc.subject Μεμβράνη μηχανικής
dc.subject Προσδιορισμός βιοηλεκτρικής αναγνώρισης
dc.title Extraction-less, rapid assay for the direct detection of 2,4,6-trichloroanisole (TCA) in cork samples en
heal.type journalArticle
heal.classification Technology
heal.classification Electrical engineering
heal.classification Τεχνολογία
heal.classification Ηλεκτρολογία Μηχανολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85133147
heal.classificationURI http://zbw.eu/stw/descriptor/18426-4
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Ηλεκτρολογία Μηχανολογία
heal.contributorName Καλτσάς, Γρηγόριος el
heal.contributorName Κίντζιος, Σπυρίδων el
heal.identifier.secondary DOI: 10.1016/j.talanta.2014.03.023
heal.language en
heal.access campus
heal.publicationDate 2014-07-01
heal.bibliographicCitation APOSTOLOU, T., PASCUAL, N., MARCO, M.-P., MOSCHOS, A., PETROPOULOS, A., et al. (2014). Extraction-less, rapid assay for the direct detection of 2,4,6-trichloroanisole (TCA) in cork samples. Talanta. [online] 125. p. 336-340. Available from: http://www.elsevier.com/[Accessed 20/03/2014] en
heal.abstract 2,4,6-trichloroanisole (TCA), the cork taint molecule, has been the target of several analytical approaches over the few past years. In spite of the development of highly efficient and sensitive tools for its detection, ranging from advanced chromatography to biosensor-based techniques, a practical breakthrough for routine cork screening purposes has not yet been realized, in part due to the requirement of a lengthy extraction of TCA in organic solvents, mostly 12% ethanol and the high detectability required. In the present report, we present a modification of a previously reported biosensor system based on the measurement of the electric response of cultured fibroblast cells membrane-engineered with the pAb78 TCA-specific antibody. Samples were prepared by macerating cork tissue and mixing it directly with the cellular biorecognition elements, without any intervening extraction process. By using this novel approach, we were able to detect TCA in just five minutes at extremely low concentrations (down to 0.2 ppt). The novel biosensor offers a number of practical benefits, including a very considerable reduction in the total assay time by one day, and a full portability, enabling its direct employment for on-site, high throughput screening of cork in the field and production facilities, without requiring any type of supporting infrastructure. en
heal.publisher Elsevier en
heal.journalName Talanta en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 1-s2.0-S0039914014002045-main.pdf
    Μέγεθος: 564.8Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες