Εμφάνιση απλής εγγραφής

dc.contributor.author Καπίρης, Παναγιώτης Γ. el
dc.contributor.author Μαθιουλάκης, Δημήτριος Σ. el
dc.contributor.author Πετρόπουλος, Αναστάσιος el
dc.contributor.author Καλτσάς, Γρηγόριος el
dc.date.accessioned 2015-05-26T07:20:59Z
dc.date.available 2015-05-26T07:20:59Z
dc.date.issued 2015-05-26
dc.identifier.uri http://hdl.handle.net/11400/11167
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com/ en
dc.subject Backward facing step
dc.subject PIV
dc.subject Thermal sensor
dc.subject Turbulence
dc.subject Θερμικοί αισθητήρες
dc.subject Στροβιλισμός
dc.title Flow reattachment point detection via thermal sensors en
heal.type journalArticle
heal.secondaryTitle PIV evaluation en
heal.generalDescription 25th Eurosensors Conference. Athens, Greece. 4-7 September, 2011. Code 88600 en
heal.classification Technology
heal.classification Electrical engineering
heal.classification Τεχνολογία
heal.classification Ηλεκτρολογία Μηχανολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85133147
heal.classificationURI http://zbw.eu/stw/descriptor/18426-4
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Ηλεκτρολογία Μηχανολογία
heal.identifier.secondary DOI: 10.1016/j.proeng.2011.12.121
heal.language en
heal.access campus
heal.publicationDate 2011
heal.bibliographicCitation KAPIRIS, P.G., MATHIOULAKIS, D.S., PETROPOULOS, A. & KALTSAS, G. (2011). Flow reattachment point detection via thermal sensors: PIV evaluation. Procedia Engineering. [online] 25. p. 487-490. Available from: http://www.elsevier.com/[Accessed 08/01/2012] en
heal.abstract Recent advances in flow control have the potential for significant impact on the engineering design. Fluidic flow control is a method for altering flows over aerodynamic surfaces which does not rely upon altering the physical shape of the surface (typically through moving control surfaces such as flaps). The steady air flow along a basic geometry of a backward facing step is used to study the alterations of the resulting recirculation area ether spontaneously or by applying pulsating fluid injection below the edge of the step as control actuator. The PIV method is used to monitor the velocity field and determine the reattachment point. Applying flow sensors based on hot wire anemometry on the bottom wall boundary it is possible to estimate parameters such as the recirculation length or even the region of intense turbulent activity as compared and verified by the PIV. Preliminary measurements by thermal sensors reveals fingerprints of the reattachment zone applying time-frequency analysis. en
heal.publisher Elsevier en
heal.journalName Procedia Engineering en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 1-s2.0-S1877705811057900-main.pdf
    Μέγεθος: 1.125Mb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες