Εμφάνιση απλής εγγραφής

dc.contributor.author Πετρόπουλος, Αναστάσιος el
dc.contributor.author Παγώνης, Δημήτριος-Νικόλαος el
dc.contributor.author Καλτσάς, Γρηγόριος el
dc.date.accessioned 2015-05-26T07:26:35Z
dc.date.available 2015-05-26T07:26:35Z
dc.date.issued 2015-05-26
dc.identifier.uri http://hdl.handle.net/11400/11168
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com/ en
dc.subject Adjustable sensitivity
dc.subject Microfluidic flow sensor
dc.subject PCB-MEMS
dc.subject Ρυθμιζόμενη ευαισθησία
dc.subject Μικρορροϊκός αισθητήρας ροής
dc.title A multi-range PCB-MEMS microfluidic flow sensor with adjustable sensitivity en
heal.type journalArticle
heal.classification Technology
heal.classification Electrical engineering
heal.classification Τεχνολογία
heal.classification Ηλεκτρολογία Μηχανολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85133147
heal.classificationURI http://zbw.eu/stw/descriptor/18426-4
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Ηλεκτρολογία Μηχανολογία
heal.identifier.secondary DOI: 10.1016/j.proeng.2011.12.196
heal.language en
heal.access campus
heal.publicationDate 2011
heal.bibliographicCitation PETROPOULOS, A., PAGONIS, D.-N. & KALTSAS, G. (2011). A multi-range PCB-MEMS microfluidic flow sensor with adjustable sensitivity. Procedia Engineering. [online] 25. p. 799-802. Available from: http://www.elsevier.com/[Accessed 08/01/2012] en
heal.abstract The complete characterization of a polymer microfluidic flow sensor is presented in this paper. The device fabrication is based on a combination of PCB and MEMS techniques, enabling effective thermal isolation and direct communication to the macroworld. The sensor performance can be tuned based on the precise definition of structural and operational parameters, these being the microchannel crossection, the sensing element positioning, and the sensor operating principle. By combining the aforementioned parameters, an extended measurement range and high sensitivity in specified flow rate regions can be achieved. en
heal.publisher Elsevier en
heal.journalName Procedia Engineering en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 1-s2.0-S1877705811058656-main.pdf
    Μέγεθος: 293.4Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες