Εμφάνιση απλής εγγραφής

dc.contributor.author Μουτζούρης, Κωνσταντίνος Ι. el
dc.contributor.author Adler, Florian en
dc.contributor.author Sotier, Florian en
dc.contributor.author Träutlein, Daniel en
dc.contributor.author Leitenstorfer, Alfred en
dc.date.accessioned 2015-06-05T16:38:45Z
dc.date.issued 2015-06-05
dc.identifier.uri http://hdl.handle.net/11400/15154
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.osa.org/ en
dc.subject Confocal microscopy
dc.subject Femtosecond fiber lasers
dc.subject Frequency metrology
dc.subject Pump power levels
dc.subject Μικροσκοπία συνεστίασης
dc.subject Μετρολογία συχνότητας
dc.title Multimilliwatt ultrashort pulses continuously tunable in the visible from a compact fiber source en
heal.type journalArticle
heal.classification Technology
heal.classification Electrical engineering
heal.classification Τεχνολογία
heal.classification Ηλεκτρολογία Μηχανολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85133147
heal.classificationURI http://zbw.eu/stw/descriptor/18426-4
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Ηλεκτρολογία Μηχανολογία
heal.keywordURI http://id.loc.gov/authorities/subjects/sh90001543
heal.identifier.secondary DOI: 10.1364/OL.31.001148
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.publicationDate 2006-04-15
heal.bibliographicCitation MOUTZOURIS, K.I., ADLER, F., SOTIER, F., TRAUTLEIN, D. & LEITENSTORFER, A. (2006). Multimilliwatt ultrashort pulses continuously tunable in the visible from a compact fiber source. Optics Letters. [online] 31 (8). p. 1148-1150. Available from: http://www.osa.org/ en
heal.abstract We report on a single-pass device that efficiently converts the broadband near-infrared output from a femtosecond fiber laser into a narrow spectrum in the visible. With fan-out poled MgO:LiNbO3 we obtain subpicosecond, continuously tunable pulses in the 520-700 nm range. Conversion efficiencies as high as 30% are observed at typical pump power levels of 30 mW, corresponding to average output powers up to 9.5 mW. The specifications of our device are ideal for applications in confocal microscopy and frequency metrology. en
heal.publisher Optical Society of America en
heal.journalName Optics Letters en
heal.journalType peer-reviewed
heal.fullTextAvailability false


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες