Εμφάνιση απλής εγγραφής

dc.contributor.author Γεωργίου, Μαρία el
dc.contributor.author Λούντος, Γεώργιος el
dc.contributor.author Δαυίδ, Στράτος Λ. el
dc.contributor.author Παπαδημήτρουλας, Παναγιώτης Γ. el
dc.contributor.author Λιάκου, Π. el
dc.date.accessioned 2015-06-05T17:21:58Z
dc.date.available 2015-06-05T17:21:58Z
dc.date.issued 2015-06-05
dc.identifier.uri http://hdl.handle.net/11400/15167
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://iopscience.iop.org/1748-0221/ en
dc.subject Gamma camera
dc.subject SPECT
dc.subject PET PET/CT
dc.subject Coronary CT angiography (CTA)
dc.subject Intraoperative probes
dc.subject Κάμερα Γάμμα
dc.subject Υπολογιστική τομογραφία εκπομπής μονήρους φωτονίου
dc.subject Τομογραφία εκπομπής ποζιτρονίων/ αξονική τομογραφία
dc.subject Αξονική στεφανιαία αγγειογραφία
dc.subject Διεγχειρητικές ανιχνευτές
dc.title Optimization of a gamma imaging probe for axillary sentinel lymph mapping en
heal.type journalArticle
heal.classification Medicine
heal.classification Technology
heal.classification Ιατρική
heal.classification Τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://zbw.eu/stw/descriptor/10470-6
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Τεχνολογία
heal.contributorName Γεωργούλιας, Παναγιώτης el
heal.identifier.secondary DOI: 10.1088/1748-0221/7/09/P09010
heal.language en
heal.access campus
heal.recordProvider Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2012-09
heal.bibliographicCitation Georgiou, M., Loudos, G., David, S., Papadimitroulas, P., Liakou, P., et al. (2012) Optimization of a gamma imaging probe for axillary sentinel lymph mapping. "Journal of Instrumentation", 7 (3). Available from: http://iopscience.iop.org/1748-0221/7/09/P09010/ [Accessed: 05/06/2015]. en
heal.abstract Sentinel lymph node (SLN) mapping is a technique for assessing whether early-stage invasive breast cancer has metastasized, thus determining prognosis and treatment options. SLN identification is achieved using the blue-dye and radioactive colloids techniques, which are sometimes combined with lymphoscintigraphy. Furthermore, intra-operative gamma acoustic probes, as well as gamma imaging probes are used during surgery. The purpose of this study is the construction of a gamma probe for sentinel lymph node imaging and its optimization in terms of sensitivity with respect to spatial resolution. The reference probe has small field of view (2.5 × 2.5 cm2) and is based on a position sensitive photomultiplier tube (PSPMT) coupled to a pixellated CsI(Tl) scintillator. Following experimental validation, we simulated the system using the GATE Monte Carlo toolkit (GATE v6.1) and modeled various collimator geometries, in order to evaluate their performance and propose the optimal configuration. The constraints of the proposed gamma imaging probe are i) sensitivity close to 2 cps/kBq and ii) spatial resolution equal to 6 mm at 2 cm source-to-collimator distance and ~ 10 mm at 5 cm. An integrated structure that achieves those requirements is a tungsten collimator with 2 × 2 mm2square holes, 16 mm thickness, 0.15 mm septa, where each CsI(Tl) 2 × 2 × 5 mm3 crystal pixel is placed inside the collimator. en
heal.publisher Allport, Phil en
heal.journalName Journal of Instrumentation en
heal.journalType peer-reviewed
heal.fullTextAvailability true