Εμφάνιση απλής εγγραφής

dc.contributor.author Γεωργίου, Μαρία el
dc.contributor.author Φυσικόπουλος, Ελευθέριος el
dc.contributor.author Λούντος, Γεώργιος el
dc.contributor.author Δαυίδ, Στράτος Λ. el
dc.date.accessioned 2015-06-06T13:01:58Z
dc.date.available 2015-06-06T13:01:58Z
dc.date.issued 2015-06-06
dc.identifier.uri http://hdl.handle.net/11400/15308
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com/science/article/pii/S1120179715000708 en
dc.subject Φωτοπολλαπλασιαστές πυριτίου
dc.subject φωτο-ανιχνευτής
dc.subject ανιχνευτές ιατρικής απεικόνισης
dc.subject Silicon photomultipliers
dc.subject photo-detector
dc.subject medical imaging detectors
dc.title Evaluation of a SiPM array coupled to a Gd3Al2Ga3O12: Ce (GAGG: Ce) discrete scintillator en
heal.type journalArticle
heal.classification Τεχνολογία
heal.classification Ιατρική
heal.classification Technology
heal.classification Medicine
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85133147
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.identifier.secondary DOI: 10.1016/j.ejmp.2015.03.008
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2014-12-29
heal.bibliographicCitation David, S., Georgiou, M., Fysikopoulos, E. and Loudos, G. (2014) Evaluation of a SiPM array coupled to a Gd3Al2Ga3O12: Ce (GAGG: Ce) discrete scintillator. Physica Medica. Available from: http://www.sciencedirect.com [Accessed 06/06/2015] en
heal.abstract Purpose: In this study, we present the results of the evaluation of the SensL ArraySL-4 photo-detector, coupled to a 6×6 GAGG:Ce scintillator array, with 2×2×5mm3 crystal size elements for possible applications in medical imaging detectors with focus in PET applications. Experimental evaluation was carried out with 22Na and 137Cs radioactive sources and the parameters studied were energy resolution and peak to valley ratio. Methods: ArraySL-4 is a commercially available, 4×4 array detector covering an active area of 13.4mm2. The GAGG:Ce scintillator array used in this study has 0.1mm thickness BaSO4 reflector material between the crystal elements. A symmetric resistive voltage division matrix was applied, which reduces the 16 outputs of the array to 4 position signals. A Field Programmable Gate Array was used for triggering and digital processing of the signal pulses acquired using free running Analog to Digital Converters. Results: Raw images and horizontal profiles of the 6×6 GAGG:Ce scintillator array produced under 511keV and 662keV excitation are illustrated. Moreover, the energy spectra obtained with 22Na and 137Cs radioactive sources from a single 2×2×5mm3 GAGG:Ce scintillator are shown. The peak to valley ratio and the mean energy resolution values are reported. Conclusions: The acquired raw image of the GAGG:Ce crystal array under 511keV excitation shows a clear visualization of all discrete scintillator elements with a mean peak to valley ratio equal to 40. The mean energy resolution was measured equal to 10.5% and 9% respectively under 511keV and 662keV irradiation. en
heal.publisher Elsevier en
heal.journalName Physica Medica en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 1-s2.0-S1120179715000708-main.pdf
    Μέγεθος: 466.4Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες