Εμφάνιση απλής εγγραφής

dc.contributor.author Φυλλαδιτάκης, Εμμανουήλ Δ. el
dc.contributor.author Μορώνης, Αντώνιος el
dc.contributor.author Κιούσης, Κωνσταντίνος Ν. el
dc.date.accessioned 2015-06-06T16:33:26Z
dc.date.available 2015-06-06T16:33:26Z
dc.date.issued 2015-06-06
dc.identifier.uri http://hdl.handle.net/11400/15335
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.researchgate.net/publication/262971810_Experimental_evaluation_of_a_needle-to-grid_EHD_pump_prototype_for_semiconductor_cooling_applications en
dc.subject Ψύξη
dc.subject Ηλεκτροϋδροδυναμική
dc.subject Αντλίες αέρα
dc.subject Απαγωγή της θερμότητας
dc.subject Εφαρμογές ψύξης
dc.subject Cooling
dc.subject Electrohydrodynamics
dc.subject Air pumps
dc.subject Convection cooling
dc.subject Cooling applications
dc.title Experimental evaluation of a needle-to-grid EHD pump prototype for semiconductor cooling applications en
heal.type journalArticle
heal.classification Ηλεκτρονική
heal.classification Μηχανική υπολογιστών
heal.classification Electronics
heal.classification Computer engineering
heal.classificationURI **N/A**-Ηλεκτρονική
heal.classificationURI **N/A**-Μηχανική υπολογιστών
heal.classificationURI http://zbw.eu/stw/descriptor/10455-2
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85029495
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85032186
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85042145
heal.identifier.secondary ISSN: 19984464
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Ενεργειακής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2014
heal.bibliographicCitation Fylladitakis, E.D., Moronis, A.X. and Kiousis, K.N. (2014) Experimental evaluation of a needle-to-grid EHD pump prototype for semiconductor cooling applications. International Journal of Circuits, Systems and Signal Processing. [Online] 8, pp.337-342. Available from: http://www.researchgate.net [Accessed 06/06/2015] en
heal.abstract A parametric study of a single needle-to-grid EHD air pump, intended for semiconductor cooling applications, is being presented in this paper. The effect of the distance between the emitter and collector electrodes, as well as the radius of the collector's grid wires, is being examined. To that end, several experimental EHD pump prototypes have been fabricated and their performance has been investigated. The experiments demonstrate that this simple and low-cost design is capable of producing usable results, depending on the space and voltage restrictions of the application, for emitter to collector distances greater than 15 mm. en
heal.journalName International Journal of Circuits, Systems and Signal Processing en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 0c960539749645ec87000000.pdf
    Μέγεθος: 727.8Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες