Εμφάνιση απλής εγγραφής

dc.contributor.author Κιούσης, Κωνσταντίνος Ν. el
dc.contributor.author Μορώνης, Αντώνιος el
dc.date.accessioned 2015-06-06T16:44:14Z
dc.date.available 2015-06-06T16:44:14Z
dc.date.issued 2015-06-06
dc.identifier.uri http://hdl.handle.net/11400/15338
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.researchgate.net/profile/Antonios_Moronis/publication/232274282_Experimental_Investigation_of_EHD_Flow_in_Wire_to_Cylinder_Electrode_Configuration/links/09e41507ff21053e48000000.pdf en
dc.subject Ηλεκτρόδια κυλίνδρου
dc.subject Ηλεκτροϋδροδυναμική
dc.subject Πειραματικές έρευνες
dc.subject Ιωνικό ανέμου
dc.subject Λειτουργίες του συστήματος τροφοδοσίας
dc.subject Cylinder electrodes
dc.subject Electrohydrodynamic
dc.subject Experimental investigations
dc.subject Ionic wind
dc.subject Power system operations
dc.title Experimental investigation of ehd flow in wire to cylinder electrode configuration en
heal.type conferenceItem
heal.classification Ενέργεια
heal.classification Ηλεκτρονική
heal.classification Energy
heal.classification Electronics
heal.classificationURI **N/A**-Ενέργεια
heal.classificationURI **N/A**-Ηλεκτρονική
heal.classificationURI http://zbw.eu/stw/descriptor/14175-2
heal.classificationURI http://zbw.eu/stw/descriptor/10455-2
heal.identifier.secondary DOI: 10.2316/P.2011.714-115
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Ενεργειακής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2011-06-22
heal.bibliographicCitation Kiousis, K.N. and Moronis, A.X. (2011) Experimental investigation of ehd flow in wire to cylinder electrode configuration. Proceedings of the IASTED International Conference on Power and Energy Systems, EuroPES 2011. IASTED International Conference on Power and Energy Systems, EuroPES 2011. Crete, Greece en
heal.abstract The electro-hydrodynamic (EHD) flow known as "ionic wind", which takes place in the area between a wire to cylinder electrode configuration under high voltage dc application, was studied. Two set of measurements were carried out in order to determine the relationship between corona discharge current, generated thrust, wind velocity and the applied voltage. The dependence of the EHD flow parameters on the cylinder radius R and the electrode distance d were examined, while the wire radius r and the electrode length L were kept constant at 25/urn and 300mm respectively. The experimental investigation confirmed the corona discharge current to voltage relationship according to Townsend's formula [1], with a very good agreement of the experimental results with theoretical expectations. The force to voltage relationship fits very well to a quadratic polynomial equation. The wind velocity-voltage relationship can be approximated by a linear equation. Parametric analysis showed that increased cylinder radius results in increased current, force and wind velocity with respect to the applied voltage. In contrary, increased electrode distance reduces current, force and wind velocity with respect to the applied high voltage. en
heal.fullTextAvailability true
heal.conferenceName Proceedings of the IASTED International Conference on Power and Energy Systems, EuroPES 2011 en
heal.conferenceItemType full paper


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Paper Reprint Proceedings ...
    Μέγεθος: 662.2Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες