Εμφάνιση απλής εγγραφής

dc.contributor.author Παπουτσάκη, Μαριάνθη - Βασιλική el
dc.contributor.author Παππάς, Ευάγγελος el
dc.contributor.author Παπαδάκης, Αντώνιος el
dc.contributor.author Βαρβέρης, Κωνσταντίνος el
dc.contributor.author Δαμηλάκης, Ιωάννης el
dc.date.accessioned 2015-06-06T17:09:16Z
dc.date.available 2015-06-06T17:09:16Z
dc.date.issued 2015-06-06
dc.identifier.uri http://hdl.handle.net/11400/15345
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.hindawi.com en
dc.subject Δοσομετρικά χαρακτηριστικά
dc.subject Temporal stability
dc.subject Χρονική σταθερότητα
dc.subject Δοσολογία
dc.title Dosimetric characteristics of N-vinylpyrrolidone based polymer gels en
heal.type journalArticle
heal.secondaryTitle utilization depending on dose range en
heal.classification Medicine
heal.classification Radiology, Medical
heal.classification Ιατρική
heal.classification Ραδιολογία, Ιατρική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85110777
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ραδιολογία, Ιατρική
heal.contributorName Μαρής, Θωμάς el
heal.identifier.secondary DOI: 10.1088/1742-6596/444/1/012068
heal.language en
heal.access campus
heal.publicationDate 2013
heal.bibliographicCitation Papoutsaki, M.-V., Pappas, E., Papadakis, A., Varveris, C., Damilakis, J. et al. (2013) Dosimetric characteristics of N-vinylpyrrolidone based polymer gels: Utilization depending on dose range. "Journal of Physics: Conference Series", 444 (1) en
heal.abstract In this study, two types of normoxic N-vinylpyrrolidone based polymer gel, VIPET1v and VIPET2v, were presented. VIPET2v had the double amount of monomer compared to the VIPET1v. The influence of this difference in the dosimetric characteristics of the polymer gel dosimeters was investigated. The doubling in N-vinylpyrrolidone concentration increased the dose sensitivity in the linear dose range region and improved the dose resolution at 95% confidence level for lower doses (D<10Gy). Unfortunately, this increase in concentration reduced the dose range response. VIPET1v was sensitive in the dose range of 2 to 60 Gy, while VIPET2v was sensitive in the dose range of 1 to 30 Gy. Moreover, both gels showed a linear R2-dose response for one month post-irradiation time period. During this time, variations in dose sensitivity and offset values of both dosimeters were observed. Finally, the dose resolution temporal stability was studied and was eventually improved by doubling the N-vinylpyrrolidone concentration. en
heal.journalName Journal of Physics: Conference Series en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες