dc.contributor.author | Μιχαήλ, Χρήστος Σ. | el |
dc.contributor.author | Φούντος, Γεώργιος Π. | el |
dc.contributor.author | Δαυίδ, Στράτος Λ. | el |
dc.contributor.author | Βαλαής, Ιωάννης Γ. | el |
dc.contributor.author | Τουτουντζής, Ανδριανός Ε. | el |
dc.date.accessioned | 2015-06-06T21:57:22Z | |
dc.date.available | 2015-06-06T21:57:22Z | |
dc.date.issued | 2015-06-07 | |
dc.identifier.uri | http://hdl.handle.net/11400/15369 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://iopscience.iop.org/1748-0221 | en |
dc.subject | Image quality | |
dc.subject | Powder scintillators | |
dc.subject | Radiation detectors | |
dc.subject | X-ray mammography | |
dc.subject | Ποιότητα απεικόνισης | |
dc.subject | Σκόνη σπινθιστήρων | |
dc.subject | Ανιχνευτές ακτινοβολίας | |
dc.subject | Μαστογραφία με ακτίνες Χ | |
dc.title | A comparative investigation of Lu2SiO5:Ce and Gd 2O2S:Eu powder scintillators for use in x-ray mammography detectors | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Chemistry | |
heal.classification | Ιατρική | |
heal.classification | Χημεία | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://zbw.eu/stw/descriptor/15638-4 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Χημεία | |
heal.contributorName | Καλύβας, Νεκτάριος Ι. | el |
heal.contributorName | Κανδαράκης, Ιωάννης Σ. | el |
heal.contributorName | Παναγιωτάκης, Γεώργιος Σ. | el |
heal.identifier.secondary | DOI: 10.1088/1748-0221/4/05/P05022 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2009 | |
heal.bibliographicCitation | Michail, C., Fountos, G., David, S., Valais, I., Toutountzis, A., et al. (2009) A comparative investigation of Lu2SiO5:Ce and Gd 2O2S:Eu powder scintillators for use in x-ray mammography detectors. "Measurement Science and Technology", 20 (10). Available from: http://iopscience.iop.org/0957-0233/20/10/104008/ [Accessed: 06/06/2015]. | en |
heal.abstract | The dominant powder scintillator in most medical imaging modalities for decades has been Gd2O2S:Tb due to the very good intrinsic properties and overall efficiency. Apart from Gd2O2S:Tb, there are alternative powder phosphor scintillators such as Lu 2SiO5:Ce and Gd2O2S:Eu that have been suggested for use in various medical imaging modalities. Gd 2O2S:Eu emits red light and can be combined mainly with digital mammography detectors such as CCDs. Lu2SiO5:Ce emits blue light and can be combined with blue sensitivity films, photocathodes and some photodiodes. For the purposes of the present study, two scintillating screens, one from Lu2SiO5:Ce and the other from Gd 2O2S:Eu powders, were prepared using the method of sedimentation. The screen coating thicknesses were 25.0 and 33.1 mg cm -2 respectively. The screens were investigated by evaluating the following parameters: the output signal, the modulation transfer function, the noise equivalent passband, the informational efficiency, the quantum detection efficiency and the zero-frequency detective quantum efficiency. Furthermore, the spectral compatibility of those materials with various optical detectors was determined. Results were compared to published data for the commercially employed 'Kodak Min-R film-screen system', based on a 31.7 mg cm-2 thick Gd2O2S:Tb phosphor. For Gd2O 2S:Eu, MTF data were found comparable to those of Gd 2O2S:Tb, while the MTF of Lu2SiO5:Ce was even higher resulting in better spatial resolution and image sharpness properties. On the other hand, Gd2O2S:Eu was found to exhibit higher output signal and zero-frequency detective quantum efficiency than Lu2SiO5:Ce. | en |
heal.publisher | Birch, David | en |
heal.journalName | Measurement Science and Technology | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: