Εμφάνιση απλής εγγραφής

dc.contributor.author Σπυρόπουλος, Βασίλειος el
dc.contributor.author Μανουσαρίδης, Γεώργιος el
dc.contributor.author Παπαθυμίου, Α. el
dc.date.accessioned 2015-06-07T14:20:11Z
dc.date.available 2015-06-07T14:20:11Z
dc.date.issued 2015-06-07
dc.identifier.uri http://hdl.handle.net/11400/15472
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://link.springer.com/chapter/10.1007%2F978-3-540-89208-3_351 el
dc.subject Dental X-ray Tubes High-Voltage
dc.subject Dental X-ray Tubes Spectrum
dc.subject Schottky CdTe-detector
dc.title A high-resolution Schottky CdTe detector based spectrometric determination method of the kilovoltage applied to dental X-ray tubes en
heal.type conferenceItem
heal.classification Medicine
heal.classification Biomedical engineering
heal.classification Ιατρική
heal.classification Βιοϊατρική τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85014237
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Βιοϊατρική τεχνολογία
heal.identifier.secondary DOI 10.1007/978-3-540-89208-3_351
heal.language en
heal.access campus
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. en
heal.publicationDate 2008-11
heal.bibliographicCitation Spyropoulos, B., Manousaridis, G. and Papathymiou, A. (2008). A high-resolution Schottky CdTe detector based spectrometric determination method of the kilovoltage applied to dental X-ray tubes. In Proceedings of 4th European Conference of the International Federation for Medical and Biological Engineering (ECIFMBE) 2008. vol.22. Antwerp, Belgium. 1479-1489 November 2008. pp 192-195. Available from: http://link.springer.com/chapter/10.1007%2F978-3-540-89208-3_351. en
heal.abstract The aim of this study was to develop a Method to determine, under clinical conditions, the diagnostic Dental X-ray equipment emitted spectra, by employing a high-resolution Schottky CdTe detector, in order to accurately determine the actually applied kilovoltage on the Tube. The analysis of X-ray spectra is important for quality assurance (QA) and quality control (QC) of Radiographic systems, and according to the European Guidelines on Radiation Protection in dental Radiology, 65–70 kV is recommended as the kilovoltage of choice for dental (intraoral) X-ray sets using AC equipment, and 60 kV for those using DC X ray sets. Since kilovoltage in this equipment is usually, either fixed, or minimally variable, the spectrometric determination of the employed High-Voltage is the most accurate method. The Molybdenum 17.5 keV and 19.6 keV characteristic spectral lines from a Mammography System and the Isotope 241Am 59.5 keV line have been employed for the Energy Calibration of the system. Dental X-ray equipment of various types and manufacturers has been tested with the developed method. en
heal.publisher Springer Berlin Heidelberg en
heal.fullTextAvailability true
heal.conferenceName 4th European Conference of the International Federation for Medical and Biological Engineering IFMBE Proceedings en
heal.conferenceItemType full paper


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: chp%3A10.1007%2F978-3-540-8920 ...
    Μέγεθος: 294.4Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες