Εμφάνιση απλής εγγραφής

dc.contributor.author Τσιλιγγίρης, Παναγιώτης el
dc.date.accessioned 2015-06-28T15:25:05Z
dc.date.available 2015-06-28T15:25:05Z
dc.date.issued 2015-06-28
dc.identifier.uri http://hdl.handle.net/11400/19993
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com en
dc.subject Bond conductance
dc.subject Solar distillation
dc.subject Ηλιακή απόσταξη
dc.subject Αγωγιμότητα δεσμών
dc.title The glazing temperature measurement in solar stills en
heal.type journalArticle
heal.secondaryTitle errors and implications on performance evaluation en
heal.classification Technology
heal.classification Energy
heal.classification Τεχνολογία
heal.classification Ενέργεια
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85133147
heal.classificationURI http://id.loc.gov/authorities/names/n42028321
heal.classificationURI **N/A**-Τεχνολογία
heal.classificationURI **N/A**-Ενέργεια
heal.identifier.secondary doi:10.1016/j.apenergy.2011.06.036
heal.language en
heal.access campus
heal.publicationDate 2011-12
heal.bibliographicCitation Tsilingiris, P. (2011) The glazing temperature measurement in solar stills – Errors and implications on performance evaluation. "Applied Energy", 88 (12), p.4936-4944 en
heal.abstract Although the brine temperature measurement in solar stills would be more or less conventional, the precise condensing surface temperature measurement, appears to present a significant difficulty to measure. In the present investigation, an analysis is developed aiming to underline the parameters affecting the glazing surface temperature measurement and a series of field measurements are presented, aiming to identify and evaluate the errors associated to the measurement of this crucial physical quantity. It is derived that among other reasons the surface temperature measurement accuracy may strongly be degraded owing to the sensor tip overheating due to the radiation absorption, as well as to the development of poor bond conductance between sensor bead and glazing surface. It may also be degraded owing to the temperature drop across the glazing thickness and the non-uniform temperature distribution over the entire condensing surface area, something that makes the selection of the appropriate location of the particular temperature transducer necessary. Based on the derived measurements, an order of magnitude analysis is employed for the approximate evaluation of error range in the condensing surface temperature measurement. This, which depending on specific conditions was found to vary between about 1 and 2 °C, was employed to demonstrate the implications and approximate conditions under which its effect could become excessively high in ordinary solar still investigations en
heal.journalName Applied Energy en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 1-s2.0-S0306261911004259-main.pdf
    Μέγεθος: 419.4Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες