Εμφάνιση απλής εγγραφής

dc.contributor.author Γαλιατσάτος, Αριστείδης el
dc.date.accessioned 2014-12-16T23:34:31Z
dc.date.issued 2014-12-17
dc.identifier.uri http://hdl.handle.net/11400/2886
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Dental care
dc.subject Silicoater
dc.subject Kevloc
dc.subject Bond strength
dc.subject Adhesion
dc.subject Resin concrete
dc.subject Alloy plating
dc.subject Οδοντική θεραπευτική
dc.subject Οδοντική προσθετική
dc.subject Οδοντική χειρουργική
dc.subject Κράμα
dc.subject Εφαρμογή
dc.subject Ρητίνη
dc.subject Σύστημα Kevloc
dc.subject Τεχνική silicoater
dc.title A comparison of the adhesive strengths of two resin to metal bonding systems en
heal.type journalArticle
heal.classification Medicine
heal.classification Surgery--Instruments--Sterilization
heal.classification Ιατρική
heal.classification Δόντια
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh2001008965
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Δόντια
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85036869
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85000861
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85113143
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85003720
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Επαγγελμάτων Υγείας και Πρόνοιας. Τμήμα Οδοντική Τεχνολογίας. el
heal.publicationDate 1999
heal.bibliographicCitation Galiatsatos, A. (1999). A comparison of the adhesive strengths of two resin to metal bonding systems. "Hellenic Dental Journal". 1:51-66 el
heal.abstract Polymer materials for the veneers o f fixed prostheses commonly require retention elements on metal framework, because there is no chemical adhesion. The use o f retention elements, however, is related to certain problems and the lack o f chemical bond allows the creation o f marginal gaps at the resin - metal interface, due to the different thermal expansion coefficients of the two materials. The development o f the chemical resin - to metal bonding could resolve this problem and also reduce the need for mechanical retention on metal frameworks. The aim o f this study was to evaluate the bond strength o f two current systems after wet storage and intesive thermocycling program. Two resin to metal bonding systems were tested: Silicoater MD - Dentacolor and rtglass - Kevloc. Three dental alloys were used: Wiron 99 (Ni - Cr, Bego Co.), Wirolloy (Ni - Cr, Bego Co.) and Wirobond C (Co - Cr, Bego Co.). The bond strengths between resin and metal were determined by the use of the four - point flexure test (4 FPBT). Before this, all the samples were subjected to a thermocycling program that included 1500 thermal cycles between 5°C - 55°C. This study indicated that the Silicoater MD - Dentacolor system can provide stable bonding o f resin to metal substructures. On the other hand, the Artglass - Kevloc system demostrated bond failures after thermocycling and indicated unstable bonding or weak bond strengths. For this system, additional in vitro research is required to investigate the mechanism o f bond weakening after thermocycling. en
heal.publisher [χ.ό.] el
heal.journalName Hellenic Dental Journal en
heal.journalType peer-reviewed
heal.fullTextAvailability true
heal.dateCreated 1998-06-01


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: A COMPARISON OF THE ADHESIVE ...
    Μέγεθος: 170.3Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες