dc.contributor.author | Γαλιατσάτος, Αριστείδης | el |
dc.date.accessioned | 2014-12-16T23:34:31Z | |
dc.date.issued | 2014-12-17 | |
dc.identifier.uri | http://hdl.handle.net/11400/2886 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | Dental care | |
dc.subject | Silicoater | |
dc.subject | Kevloc | |
dc.subject | Bond strength | |
dc.subject | Adhesion | |
dc.subject | Resin concrete | |
dc.subject | Alloy plating | |
dc.subject | Οδοντική θεραπευτική | |
dc.subject | Οδοντική προσθετική | |
dc.subject | Οδοντική χειρουργική | |
dc.subject | Κράμα | |
dc.subject | Εφαρμογή | |
dc.subject | Ρητίνη | |
dc.subject | Σύστημα Kevloc | |
dc.subject | Τεχνική silicoater | |
dc.title | A comparison of the adhesive strengths of two resin to metal bonding systems | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Surgery--Instruments--Sterilization | |
heal.classification | Ιατρική | |
heal.classification | Δόντια | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh2001008965 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Δόντια | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85036869 | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85000861 | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85113143 | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85003720 | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.recordProvider | Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Επαγγελμάτων Υγείας και Πρόνοιας. Τμήμα Οδοντική Τεχνολογίας. | el |
heal.publicationDate | 1999 | |
heal.bibliographicCitation | Galiatsatos, A. (1999). A comparison of the adhesive strengths of two resin to metal bonding systems. "Hellenic Dental Journal". 1:51-66 | el |
heal.abstract | Polymer materials for the veneers o f fixed prostheses commonly require retention elements on metal framework, because there is no chemical adhesion. The use o f retention elements, however, is related to certain problems and the lack o f chemical bond allows the creation o f marginal gaps at the resin - metal interface, due to the different thermal expansion coefficients of the two materials. The development o f the chemical resin - to metal bonding could resolve this problem and also reduce the need for mechanical retention on metal frameworks. The aim o f this study was to evaluate the bond strength o f two current systems after wet storage and intesive thermocycling program. Two resin to metal bonding systems were tested: Silicoater MD - Dentacolor and rtglass - Kevloc. Three dental alloys were used: Wiron 99 (Ni - Cr, Bego Co.), Wirolloy (Ni - Cr, Bego Co.) and Wirobond C (Co - Cr, Bego Co.). The bond strengths between resin and metal were determined by the use of the four - point flexure test (4 FPBT). Before this, all the samples were subjected to a thermocycling program that included 1500 thermal cycles between 5°C - 55°C. This study indicated that the Silicoater MD - Dentacolor system can provide stable bonding o f resin to metal substructures. On the other hand, the Artglass - Kevloc system demostrated bond failures after thermocycling and indicated unstable bonding or weak bond strengths. For this system, additional in vitro research is required to investigate the mechanism o f bond weakening after thermocycling. | en |
heal.publisher | [χ.ό.] | el |
heal.journalName | Hellenic Dental Journal | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true | |
heal.dateCreated | 1998-06-01 |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: