Εμφάνιση απλής εγγραφής

dc.contributor.author Τσόλκα, Παναγιώτα el
dc.contributor.author Altay, O.T. el
dc.contributor.author Preiskel, Harold W. el
dc.date.accessioned 2014-12-23T13:00:48Z
dc.date.issued 2014-12-23
dc.identifier.uri http://hdl.handle.net/11400/3116
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Prosthodontics
dc.subject Dental abutments
dc.subject denture movement
dc.subject in vitro studies
dc.subject Οδοντική προσθετική
dc.subject τεχνητή οδοντοστοιχία
dc.subject κολόβωμα
dc.subject εργαστηριακή μελέτη
dc.title The Effect of the Major Connector on Abutment Tooth and Denture Base Movement en
heal.type journalArticle
heal.secondaryTitle an In Vitro Study en
heal.classification Medicine
heal.classification Surgery--Patients
heal.classification Ιατρική
heal.classification Χειρουργική - Ασθενείς
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh2001008968
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Χειρουργική - Ασθενείς
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85107621
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85036854
heal.keywordURI http://lod.nal.usda.gov/47062
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Επαγγελμάτων Υγείας και Πρόνοιας. Τμήμα Οδοντική Τεχνολογίας. el
heal.publicationDate 1990
heal.bibliographicCitation Tsolka, D., Altay, O .T. & Preiskel, H. W. (1990) The Effect of the Major Connector on Abutment Tooth and Denture Base Movement: An In Vitro Study. "The International Journal of Prosthodontics". 3 (6). p. 545-549 el
heal.abstract This in vitro study investigated the effect of the major connector on distal abutment tooth and denture base movements when loads were applied to a partial denture with extracoronal attachments. A brass mechanism was constructed for load application, and the abutment and base movements were measured in three planes using a kinesiograph. It was determined that cutting the major connector affected the degree of abutment tooth movement but not the direction. After cutting the major connector, the base movement increased in all three planes with the different forces applied. The direction of the base movement changed only in the buccolingual plane. en
heal.publisher [χ.ό.] el
heal.journalName The International Journal of Prosthodontics en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: THE EFFECT OF THE MAJOR CONNECTOR ...
    Μέγεθος: 139.9Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες