dc.contributor.author | Zaky, A. A. | en |
dc.contributor.author | Megahed, I. Y. | en |
dc.contributor.author | Ευαγγέλου, Χρήστος Α. | el |
dc.date.accessioned | 2015-01-08T17:56:25Z | |
dc.date.available | 2015-01-08T17:56:25Z | |
dc.date.issued | 2015-01-08 | |
dc.identifier.uri | http://hdl.handle.net/11400/3564 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | IOPscience | en |
dc.subject | Mineral oil | |
dc.subject | Breakdown voltage | |
dc.subject | Ορυκτέλαιο | |
dc.subject | Τάση διάσπασης | |
dc.title | Effect of polarity and gap length on the breakdown characteristics of mineral oil for non-uniform fieldsZa | en |
heal.type | journalArticle | |
heal.classification | Technology | |
heal.classification | Chemical technology | |
heal.classification | Τεχνολογία | |
heal.classification | Χημική τεχνολογία | |
heal.classificationURI | http://zbw.eu/stw/descriptor/10470-6 | |
heal.classificationURI | http://skos.um.es/unescothes/C00565 | |
heal.classificationURI | **N/A**-Τεχνολογία | |
heal.classificationURI | **N/A**-Χημική τεχνολογία | |
heal.keywordURI | http://lod.nal.usda.gov/53075 | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85016671 | |
heal.identifier.secondary | doi:10.1088/0022-3727/9/8/003 | |
heal.language | en | |
heal.access | free | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Ενεργειακής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 1976 | |
heal.bibliographicCitation | Zaky, A., Megahed, I. and Evangelou, C. (1976). Effect of polarity and gap length on the breakdown characteristics of mineral oil for non-uniform fields. Journal of Physics D: Applied Physics. 9(8). pp. 77-79. Available from: http://iopscience.iop.org/. | en |
heal.abstract | The direct breakdown voltage of degassed transformer oil has been measured as a function of gap length using point-sphere electrodes, for both polarities of the point. Although changing the material of the sphere electrode altered the magnitude of the breakdown voltage for both point polarities, the critical gap length at which the breakdown voltage was the same for both polarities remained unchanged. This critical gap length was markedly reduced by the presence of dissolved oxygen. | en |
heal.publisher | [χ.ό.] | el |
heal.journalName | Journal of Physics D: Applied Physics | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |