Εμφάνιση απλής εγγραφής

dc.contributor.author Ματσόπουλος, Γεώργιος Κ. el
dc.contributor.author Ασβεστάς, Παντελής Α. el
dc.contributor.author Δελήμπασης, Κωνσταντίνος Κ. el
dc.contributor.author Κουλουλίας, Βασίλειος el
dc.contributor.author Ουζούνογλου, Νικόλαος Κ. el
dc.date.accessioned 2015-01-14T11:53:48Z
dc.date.available 2015-01-14T11:53:48Z
dc.date.issued 2015-01-14
dc.identifier.uri http://hdl.handle.net/11400/4033
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://iopscience.iop.org/ en
dc.subject Electronic portal
dc.subject Digitally reconstructed radiographs
dc.subject Ηλεκτρονική πύλη
dc.subject Ψηφιακή ανακατασκευή ακτινογραφίας
dc.title Registration of electronic portal images for patient set-up verification en
heal.type journalArticle
heal.classification Medicine
heal.classification Medical physics
heal.classification Ιατρική
heal.classification Ιατρική φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85083001
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ιατρική φυσική
heal.contributorName Καραΐσκος, Παντελής el
heal.contributorName Σάνδηλος, Παναγιώτης el
heal.identifier.secondary doi:10.1088/0031-9155/49/14/018
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2004
heal.bibliographicCitation Matsopoulos, G., Asvestas, P., Delibasis, K., Kouloulias, V., Uzunoglu, N. et al. (July 2004). Registration of electronic portal images for patient set-up verification. Physics in Medicine and BiologyInstitute of Physics and Engineering in Medicine. 49(14). pp. 3279-3289. IOP Publishing Ltd. Available from: http://iopscience.iop.org en
heal.abstract Images acquired from an electronic portal imaging device are aligned with digitally reconstructed radiographs (DRRs) or other portal images to verify patient positioning during radiation therapy. Most of the currently available computer aided registration methods are based on the manual placement of corresponding landmarks. The purpose of the paper is twofold: (a) the establishment of a methodology for patient set-up verification during radiotherapy based on the registration of electronic portal images, and (b) the evaluation of the proposed methodology in a clinical environment. The estimation of set-up errors, using the proposed methodology, can be accomplished by matching the portal image of the current fraction of the treatment with the portal image of the baseline treatment (reference portal image) using a nearly automated technique. The proposed registration method is tested on a number of phantom data as well as on data from four patients. The phantom data included portal images that corresponded to various positions of the phantom on the treatment couch. For each patient, a set of 30 portal images was used. For the phantom data (for both transverse and lateral portal images), the maximum absolute deviations of the translational shifts were within 1.5 mm, whereas the in-plane rotation angle error was less than 0.5°. The two-way Anova revealed no statistical significant variability both within observer and between-observer measurements (P > 0.05). For the patient data, the mean values obtained with manual and the proposed registration methods were within 0.5 mm. In conclusion, the proposed registration method has been incorporated within a system, called ESTERR-PRO. Its image registration capability achieves high accuracy and both intra- and inter-user reproducibility. The system is fully operational within the Radiotherapy Department of 'HYGEIA' Hospital in Athens and it could be easily installed in any other clinical environment since it requires standardized hardware specifications and minimal human intervention. en
heal.publisher IOP Publishing Ltd en
heal.journalName Physics in Medicine and BiologyInstitute of Physics and Engineering in Medicine en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Registration of electronic portal ...
    Μέγεθος: 314.3Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες