Εμφάνιση απλής εγγραφής

dc.contributor.author Λαβδάς, Ελευθέριος el
dc.contributor.author Μαυροειδής, Παναγιώτης el
dc.contributor.author Βάσιου, Αικατερίνη el
dc.contributor.author Ροκά, Βιολέτα el
dc.contributor.author Φεζουλίδης, Ιωάννης Β. el
dc.date.accessioned 2015-01-14T22:09:51Z
dc.date.available 2015-01-14T22:09:51Z
dc.date.issued 2015-01-15
dc.identifier.uri http://hdl.handle.net/11400/4067
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com/ en
dc.subject Magnetic resonance imaging
dc.subject Τεχνούργημα Χημική μετατόπιση
dc.subject Σπονδυλική στήλη
dc.subject Μαγνητική τομογραφία
dc.subject Chemical-shift artifact
dc.subject Spine
dc.title Elimination of chemical shift artifacts of thoracic spine with contrastenhanced FLAIR imaging with fat suppression at 3.0 T en
heal.type journalArticle
heal.generalDescription Technical notes en
heal.classification Medicine
heal.classification Radiology, Medical
heal.classification Ιατρική
heal.classification Ακτινολογία, Ιατρική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85110777
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ακτινολογία, Ιατρική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85079741
heal.contributorName Βλυχού, Μαριάννα el
heal.identifier.secondary DOI: 10.1016/j.mri.2010.06.020
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας.Σχολή Επαγγελμάτων Υγείας και Πρόνοιας.Τμήμα Ραδιολογίας και Ακτινολογίας. el
heal.publicationDate 2010-12
heal.bibliographicCitation Lavdas, E., Mavroidis, P., Vassiou, K., Roka, V., Fezoulidis, I.V., et al. (2010). Elimination of chemical shift artifacts of thoracic spine with contrastenhanced FLAIR imaging with fat suppression at 3.0 T. "Magnetic Resonance Imaging". 28 (10), p.1535-1540. en
heal.abstract The purpose of this study was to assess the effect of chemical shift artifacts and fat suppression between contrast-enhanced T1-weighted fast spin-echo (FSE) sequence with fat suppression and contrast-enhanced T1-weighted fluid attenuated inversion recovery (FLAIR) sequence with fat suppression in magnetic resonance imaging (MRI) of the thoracic spine at 3.0T. Forty patients, who underwent MRI examination, were recruited and analyzed both qualitatively and quantitatively. Due to chemical shift artifacts in the T1-weighted FSE, 14 of the patients were found to be of non-diagnostic value. On the contrary, in 11 of those 14 patients, no chemical shift artifacts were observed in the T1-weighted FLAIR sequence. Regarding the efficiency of fat suppression, both sequences achieved successful fat suppression. Consequently, the use of T1-weighted FLAIR fat suppression after contrast administration sequence seems to eliminate or significantly reduce image quality deterioration stemming from chemical shift artifacts in thoracic spine examinations en
heal.publisher Elsevier Science Ltd en
heal.journalName Magnetic Resonance Imaging en
heal.journalType peer-reviewed