Εμφάνιση απλής εγγραφής

dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Κάβουρας, Διονύσης Α. el
dc.contributor.author Νικολόπουλος, Δημήτριος Σ. el
dc.contributor.author Επισκοπάκης, Α. el
dc.contributor.author Καλύβας, Νεκτάριος Ι. el
dc.date.accessioned 2015-01-16T11:24:43Z
dc.date.available 2015-01-16T11:24:43Z
dc.date.issued 2015-01-16
dc.identifier.uri http://hdl.handle.net/11400/4124
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com en
dc.subject X-ray imaging
dc.subject Angular distribution (Nuclear physics)
dc.subject Απεικόνιση με ακτίνες Χ
dc.subject Γωνιακή κατανομή
dc.title A theoretical model evaluating the angular distribution of luminescence emission in X-ray scintillating screens en
heal.type journalArticle
heal.classification Medicine
heal.classification Medicine, Physical
heal.classification Ιατρική
heal.classification Ιατρική φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85083159
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ιατρική φυσική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85005143
heal.contributorName Λαπαρίνος, Παναγιώτης el
heal.contributorName Βαλαής, Ιωάννης Γ. el
heal.contributorName Καγκάδης, Γεώργιος Χ. el
heal.contributorName Κουρκουτάς, Κωνσταντίνος Δ. el
heal.contributorName Σιανούδης, Ιωάννης Α. el
heal.contributorName Δημητρόπουλος, Νικόλαος el
heal.contributorName Νομικός, Κωνσταντίνος Δ. el
heal.contributorName Παναγιωτάκης, Γεώργιος Σ. el
heal.identifier.secondary doi:10.1016/j.apradiso.2005.11.016
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2006
heal.bibliographicCitation Kandarakis, A., Cavouras, D., Nikolopoulos, D., Episkopakis, A., Kalivas, N., et al. (April 2006). A theoretical model evaluating the angular distribution of luminescence emission in X-ray scintillating screens. Applied Radiation and Isotopes. 64(4). pp. 508–519. Elsevier Ltd. Available from: http://www.sciencedirect.com [Accessed 04/01/2006] en
heal.abstract The aim of this study was to examine the angular distribution of the light emitted from radiation-excited scintillators in medical imaging detectors. This distribution diverges from Lambert's cosine law and affects the light emission efficiency of scintillators, hence it also affects the dose burden to the patient. In the present study, the angular distribution was theoretically modeled and was used to fit experimental data on various scintillator materials. Results of calculations revealed that the angular distribution is more directional than that predicted by Lambert's law. Divergence from this law is more pronounced for high values of light attenuation coefficient and thick scintillator layers (screens). This type of divergence reduces light emission efficiency and hence it increases the incident X-ray flux required for a given level of image brightness. en
heal.publisher Elsevier Ltd en
heal.journalName Applied Radiation and Isotopes en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες