Εμφάνιση απλής εγγραφής

dc.contributor.author Λαβδάς, Ελευθέριος el
dc.contributor.author Βλυχού, Μαριάννα el
dc.contributor.author Ροκά, Βιολέτα el
dc.contributor.author Βόζνιακ, Γκρέτα el
dc.contributor.author Πρωτόγερου, Γεωργία el
dc.date.accessioned 2015-01-16T21:44:54Z
dc.date.available 2015-01-16T21:44:54Z
dc.date.issued 2015-01-16
dc.identifier.uri http://hdl.handle.net/11400/4145
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com/ en
dc.subject Τα παράσιτα κίνησης
dc.subject Τμηματικός
dc.subject Αποκατάσταση
dc.subject Motion artifacts
dc.subject Segmental
dc.subject Ρeconstruction
dc.title Artifacts in spiral CT protocols en
heal.type journalArticle
heal.secondaryTitle the importance of the spatial reconstruction en
heal.classification Medicine
heal.classification Radiology, Medical
heal.classification Ιατρική
heal.classification Ακτινολογία, Ιατρική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85110777
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ακτινολογία, Ιατρική
heal.contributorName Φεζουλίδης, Ιωάννης Β. el
heal.identifier.secondary DOI:10.1016/j.ejradi.2009.09.004
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας.Σχολή Επαγγελμάτων Υγείας και Πρόνοιας.Τμήμα Ραδιολογίας και Ακτινολογίας. el
heal.publicationDate 2009-06
heal.bibliographicCitation Lavdas, E., Vlychou, M., Roka, V., Wozniak, G., Protogerou, G., et al. (2009). Artifacts in spiral CT protocols: the importance of the spatial reconstruction." European Journal of Radiography". 1 (2). p.73-79. en
heal.abstract Purpose This study recorded and analysed streak and motion artifacts in spiral CT examinations and evaluated the elimination and minimization of them by the use of segmental reconstruction with and without alterations of the initial examination protocol. Materials and methods One hundred CT scans of the chest and 300 CT scans of the brain have been included in this study. All studies were performed by a helical CT scanner (Philips 5000 SR) with the standard protocol and were randomly selected due to the presence of either streak or motion artifacts. Segmental reconstruction was applied in all cases by the same experienced radiographer. Image evaluation was performed by two experienced radiologists using a scoring system for each artifact and a grading system for classifying post-processing images. Results Among series of images that were evaluated after the application of segmental reconstruction, brain examinations demonstrated the following results: 10.9% of the cases showed no artifact improvement, 19.6% showed slight artifact improvement 31.5% showed moderate improvement and 38% showed significant improvement. The results of chest examinations were as follows: 27% of the cases showed no artifact improvement, 23% showed slight artifact improvement, 26% showed moderate improvement and 24% of showed significant improvement. Spatial reconstruction was useless in brain CT images when a patient moved during the entire scan and in chest CT images when streak and motion artifacts co-existed. Conclusions Spatial reconstruction may improve the image quality in brain and chest CT examinations and thus may contribute to more diagnostic images. Elimination of motion artifacts is also suggested due to the limitation of intravenous contrast medium that can be administered per patient per day and in cases of non-cooperative patients. en
heal.publisher Elsevier Science Ltd en
heal.journalName European Journal of Radiography en
heal.journalType peer-reviewed
heal.fullTextAvailability true