dc.subject Screen-film radiography
dc.subject Diagnosis, Fluoroscopic
dc.subject Συστήματα ακτίνων Χ
dc.subject Ακτινοσκοπική
dc.title Image quality evaluation and patient dose assessment of medical fluoroscopic x-ray systems: a national study en
heal.type journalArticle
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh91005963
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85037495
heal.contributorName Τριτάκης, Π. el
heal.contributorName Μανουσαρίδης, Γ. el
heal.contributorName Βογιατζή, Σ. el
heal.contributorName Κηπουρός, Π. el
heal.contributorName Βόζιαρη, Αργυρώ el
heal.contributorName Καμενοπούλου, Β. el
heal.identifier.secondary doi:10.1093/rpd/ncm456
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2007
heal.bibliographicCitation Economides, S., Hourdakis, C., Kalivas, N., Kalathaki, M., Simantirakis, G., et al. (October 2007). Image quality evaluation and patient dose assessment of medical fluoroscopic x-ray systems: a national study. Radiation Protection Dosimetry. 129(4). pp. 419–425. Oxford University Press. Available from: http://rpd.oxfordjournals.org [Accessed 30/10/2007] en
heal.abstract This study presents the results from a survey conducted by the Greek Atomic Energy Commission (GAEC), during the period 1998–2003, in 530 public and private owned fluoroscopic X-ray systems in Greece. Certain operational parameters for conventional and remote control systems were assessed, according to a quality control protocol developed by GAEC on the basis of the current literature. Public (91.5%) and private (81.5%) owned fluoroscopic units exhibit high-contrast resolution values over 1 lp mm−1. Moreover, 88.5 and 87.1% of the fluoroscopic units installed in the public and private sector, respectively, present Maximum Patient Entrance Kerma Rate values lower than 100 mGy min−1. Additionally, 68.3% of the units assessed were found to perform within the acceptance limits. Finally, the third quartile of the Entrance Surface Dose Rate distribution was estimated according to the Dose Reference Level definition and found equal to 35 mGy min−1. en
heal.publisher Oxford University Press en
heal.journalName Radiation Protection Dosimetry en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες