Εμφάνιση απλής εγγραφής

dc.contributor.author Καραντάνας, Απόστολος el
dc.contributor.author Παπανικολάου, Νικόλαος el
dc.contributor.author Βάσιου, Αικατερίνη el
dc.contributor.author Λαβδάς, Ελευθέριος el
dc.date.accessioned 2015-01-19T11:33:16Z
dc.date.available 2015-01-19T11:33:16Z
dc.date.issued 2015-01-19
dc.identifier.uri http://hdl.handle.net/11400/4249
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com/ en
dc.subject Comparative studies
dc.subject Brain--Magnetic resonance imaging
dc.subject Συγκριτική μελέτη
dc.subject Μαγνητική τομογραφία εγκεφάλου
dc.title Comparison of T1-weighted spin-echo and 3D T1-weighted multi-shot Echo Planar pulse sequences in imaging the brain at it en
heal.type journalArticle
heal.classification Medicine
heal.classification Radiology, Medical
heal.classification Ιατρική
heal.classification Ακτινολογία, Ιατρική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85110777
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ακτινοβολία, Ιατρική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh99001486
heal.keywordURI http://id.loc.gov/authorities/subjects/sh2009117515
heal.identifier.secondary DOI:10.1016/S0730-725X(99)00009-0
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας.Σχολή Επαγγελμάτων Υγείας και Πρόνοιας.Τμήμα Ραδιολογίας και Ακτινολογίας. el
heal.publicationDate 1999-06
heal.bibliographicCitation Karantanas, A.H., Papanikolaou, N., Vasiou, K., and Lavdas, E. (1999). Comparison of T1-weighted spin-echo and 3D T1-weighted multi-shot Echo Planar pulse sequences in imaging the brain at it. "Magnetic Resonance Imaging". 17 (5), p.663-668. en
heal.abstract The purpose of this study was to evaluate the ability of three dimensional T1-weighted multi-shot Echo Planar Imaging (3D T1w EPI) MR pulse sequence to provide comparable to T1w Spin Echo (SE) results in various diseases of the brain, during shorter acquisition times. Thirty-six patients (aged 30-74 years) with various indications were included in the study. All examinations were performed with a 1T MR scanner with a maximum gradient strength of 15 mT/m. The SE sequence lasted 3 min 50s and the 3D T1w EPI 59s. The quantitative analysis included number of enhancing lesions, signal-to-noise ratio of the enhancing lesions and contrast-to-noise ratio (CNR) between enhancing lesions and white matter in both sequences before and after i.v. administration of 0.1 mmol/kg gadopentetate dimeglumine. In addition, the percentage increase of enhancement was measured in each lesion of each sequence. The qualitative analysis included a) conspicuity of the lesions and b) presence of artifacts. The T1w SE sequence was significantly better compared to 3D T1w EPI in all quantitative measurements with the exception of CNR of enhancing lesions before contrast administration and the percentage enhancement. The conspicuity of the lesions did not differ between the two sequences. The EPI sequence presented with significantly more artifacts. We conclude that the 3D T1w EPI sequence could not be used instead of the conventional T1w SE, in routine imaging of the brain. Its overall diagnostic capability, could be useful only in uncooperative patients en
heal.publisher Elsevier Science Ltd en
heal.journalName Magnetic Resonance Imaging en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες