dc.contributor.author | Μιχαήλ, Χρήστος Μ. | el |
dc.contributor.author | Βαλαής, Ιωάννης Γ. | el |
dc.contributor.author | Τουτουντζής, Ανδριανός Ε. | el |
dc.contributor.author | Καλύβας, Νεκτάριος Ι. | el |
dc.contributor.author | Φούντος, Γεώργιος Π. | el |
dc.date.accessioned | 2015-01-19T11:46:05Z | |
dc.date.issued | 2015-01-19 | |
dc.identifier.uri | http://hdl.handle.net/11400/4250 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | X-ray detection | |
dc.subject | X-ray imaging | |
dc.subject | Ανίχνευση ακτίνων Χ | |
dc.subject | Απεικόνιση με ακτίνες Χ | |
dc.title | Light emission efficiency of Gd2O2S:eu (GOS:Eu) powder screens under X-ray mammography conditions | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Physics | |
heal.classification | Ιατρική | |
heal.classification | Φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Φυσική | |
heal.contributorName | Ντάβιντ, Στράτος Λ. | el |
heal.contributorName | Κανδαράκης, Ιωάννης Σ. | el |
heal.contributorName | Παναγιωτάκης, Γεώργιος Σ. | el |
heal.identifier.secondary | DOI: 10.1109/TNS.2008.2007562 | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2009 | |
heal.bibliographicCitation | Michail, C., Valais, I., Toutountzis, A., Kalyvas, N., Fountos, G., et al. (January 2009). Light emission efficiency of Gd2O2S:eu (GOS:Eu) powder screens under X-ray mammography conditions. Transactions on Nuclear Science. 55(6). pp. 3703 - 3709. IEEE | en |
heal.abstract | The aim of this study was to examine Gd2O2S:Eu (also known as GOS:Eu) powder scintillator under X-ray mammography imaging conditions. For this purpose, three scintillator screens with coating thicknesses of 33.1, 46.4 and 63.1 mg/cm2 were prepared in our laboratory by sedimentation of Gd2O2S:Eu powder. Light emission efficiency and optical emission spectra of the screens were measured under X-ray excitation using X-ray tube voltages (22-49 kVp) employed in mammography. Spectral compatibility with various optical photon detectors (photodiodes, photocathodes, charge coupled devices, films) and intrinsic conversion efficiency value (0.12) were determined by using emission spectrum data. In addition, parameters related to X-ray detection and energy absorption efficiency were calculated. Gd2O2S:Eu showed peak emission in the wavelength range 620-630 nm. The 63.1 mg/cm2 phosphor screen appeared with the maximum light emission efficiency. Due to its reddish emission spectrum, Gd2O2S:Eu showed excellent compatibility with the sensitivity of many currently used photodetectors and could be considered for application in X-ray imaging especially in various digital detectors. | en |
heal.publisher | IEEE | en |
heal.journalName | Transactions on Nuclear Science | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: