Εμφάνιση απλής εγγραφής

dc.contributor.author Πατατούκας, Γ. el
dc.contributor.author Γαϊτάνης, Αναστάσιος el
dc.contributor.author Καλύβας, Νεκτάριος Ι. el
dc.contributor.author Λιαπαρίνος, Παναγιώτης Φ. el
dc.contributor.author Νικολόπουλος, Δημήτριος Σ. el
dc.date.accessioned 2015-01-19T14:51:05Z
dc.date.available 2015-01-19T14:51:05Z
dc.date.issued 2015-01-19
dc.identifier.uri http://hdl.handle.net/11400/4258
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com el
dc.subject Energy weighting
dc.subject X-ray mammography
dc.subject Ενέργεια στάθμισης
dc.subject Μαστογραφία ακτίνων Χ
dc.title The effect of energy weighting on the SNR under the influence of non-ideal detectors in mammographic applications en
heal.type journalArticle
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.contributorName Κωνσταντινίδης, Αναστάσιος Χ. el
heal.contributorName Κανδαράκης, Ιωάννης Σ. el
heal.contributorName Κάβουρας, Διονύσης Α. el
heal.contributorName Παναγιωτάκης, Γεώργιος Σ. el
heal.identifier.secondary doi:10.1016/j.nima.2006.08.019
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2006
heal.bibliographicCitation Patatoukas, G., Gaitanis, A., Kalivas, N., Liaparinos, P., Nikolopoulos, D., et al. (December 2006). The effect of energy weighting on the SNR under the influence of non-ideal detectors in mammographic applications. Nuclear Instruments and Methods in Physics Research A. 569(2). pp. 260–263. Elsevier Science Ltd. Available from: http://www.sciencedirect.com [Accessed 01/09/2006] en
heal.abstract This work investigates the effect of the energy-weighting technique on the signal to noise ratio (SNR) response of X-ray imaging detectors. So far in the literature all scintillation-detector characteristics (detection efficiency, conversion efficiency, light-attenuation effects, etc) that degrade image quality have been ignored. A theoretical evaluation of the scintillator's SNR output was carried out. An algorithm was produced to describe the variation of the weighting factor, and SNR, with respect to the anode material (Mo or W), in a particular energy range (25–40 keV), typical for mammography, using two different phantoms. Results show that under non-ideal conditions the ratio of the weighted SNR to the original SNR appears to be increasing from values that are close to unity, and under specific conditions, can reach values up to 30. For the further investigation of this method, a more complex, simulated computed tomography breast imaging system was modeled and studied for various parameters such as breast software phantoms, scintillation materials and reconstruction filters. en
heal.publisher Elsevier Science Ltd en
heal.journalName Nuclear Instruments and Methods in Physics Research A en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες