dc.contributor.author | Καραντάνας, Απόστολος | el |
dc.contributor.author | Ζιμπής, Αριστείδης | el |
dc.contributor.author | Ρουσογιάννης, Σωτήριος | el |
dc.contributor.author | Βελεσιώτου, Κωνσταντίνα | el |
dc.contributor.author | Λαβδάς, Ελευθέριος | el |
dc.date.accessioned | 2015-01-19T20:01:52Z | |
dc.date.issued | 2015-01-19 | |
dc.identifier.uri | http://hdl.handle.net/11400/4272 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | Volumetry | |
dc.subject | Υποβοηθούμενη από υπολογιστή τομογραφία | |
dc.subject | Ελεγχόμενη μελέτη | |
dc.subject | Άνθρωπος | |
dc.subject | Ανθρώπινα οστά | |
dc.subject | Ογκομετρία | |
dc.subject | Computer assisted tomography | |
dc.subject | Controlled study | |
dc.subject | Human | |
dc.subject | Human tissue | |
dc.title | In vitro orbital volume measurement using computed tomography | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Radiology, Medical | |
heal.classification | Ιατρική | |
heal.classification | Ακτινολογία, Ιατρική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85110777 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Ακτινολογία, Ιατρική | |
heal.keywordURI | http://skos.um.es/unesco6/230119 | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.recordProvider | Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας.Σχολή Επαγγελμάτων Υγείας και Πρόνοιας.Τμήμα Ραδιολογίας και Ακτινολογίας. | el |
heal.publicationDate | 1994 | |
heal.bibliographicCitation | Karantanas, A.H., Zibis, A., Rousogiannis, S., Velesiotou, C., Lavdas, E. (1994). In vitro orbital volume measurement using computed tomography. "Radiologia Diagnostica". 35 (4), p.265-268. | en |
heal.abstract | A method for measuring orbital volume using CT with contiguous 3 mm axial sections is described. The accuracy of the method is 3.2% as demonstrated by comparing the CT volume measurements with those derived directly from cadaveric human skulls. The interindividual observer variation was 5.4% for the skulls and 2.6% for the CT measurements. The intraindividual observer variation was 2.2% for the CT measurements. Within the same individual, the right and left orbital volumes were found to be within 0.57 cm3 of each other. The present study demonstrates that CT is a practical method of determining the orbital volume and could be used in the management of blow-out fractures and traumatic enophthalmos by predicting the volume of the diseased orbit from the normal one | en |
heal.publisher | [χ.ό.] | el |
heal.journalName | Radiologia Diagnostica | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | false |
Αρχεία | Μέγεθος | Μορφότυπο | Προβολή |
---|---|---|---|
Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο. |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: