dc.contributor.author Μιχαήλ, Χρήστος Μ. el
dc.contributor.author Ντάβιντ, Στράτος Λ. el
dc.contributor.author Λιαπαρίνος, Παναγιώτης Φ. el
dc.contributor.author Βαλαής, Ιωάννης Γ. el
dc.contributor.author Νικολόπουλος, Δημήτριος Σ. el
dc.date.accessioned 2015-01-20T12:58:14Z
dc.date.available 2015-01-20T12:58:14Z
dc.date.issued 2015-01-20
dc.identifier.uri http://hdl.handle.net/11400/4320
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com en
dc.subject X-ray imaging
dc.subject Phosphor screens
dc.subject Απεικόνιση με ακτίνες Χ
dc.subject Οθόνες φωσφόρου
dc.title Evaluation of the imaging performance of LSO powder scintillator for use in X-ray mammography en
heal.type journalArticle
heal.generalDescription Proceedings of the 10 th International Symposium on Radiation Physics-ISRP 10 en
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.contributorName Καλύβας, Νεκτάριος Ι. el
heal.contributorName Τουτουντζής, Ανδριανός Ε. el
heal.contributorName Κάβουρας, Διονύσης Α. el
heal.contributorName Κανδαράκης, Ιωάννης Σ. el
heal.contributorName Παναγιωτάκης, Γεώργιος Σ. el
heal.identifier.secondary doi:10.1016/j.nima.2007.05.234
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2007
heal.bibliographicCitation Michail, C., David, S., Liaparinos, P., Valais, I., Nikolopoulos, D., et al. (September 2007). Evaluation of the imaging performance of LSO powder scintillator for use in X-ray mammography. Nuclear Instruments and Methods in Physics Research A. 580(1). pp. 558–561. Elsevier Science Ltd. Available from: http://www.sciencedirect.com [Accessed 24/05/2007] en
heal.abstract The aim of the present study was to evaluate the imaging performance of Lu2SiO5:Ce (LSO:Ce) powder scintillator for use in X-ray detectors used in mammography. LSO:Ce scintillator is a high efficiency, fast emitting material, which in single-crystal form is used in positron emission tomography detectors. A scintillating screen, with a coating thickness of 25 mg/cm2, was prepared in our laboratory from commercially available LSO:Ce powder (Phosphor Technology Ltd.). The imaging performance of the screen was assessed by experimental determination of the modulation transfer function (MTF) and the noise transfer function (NTF). Experimental MTF values were compared to data obtained by a custom Monte Carlo simulation program. Screen irradiation was performed under exposure conditions employed in mammographic applications (27 kVp, 63 mAs). MTF was determined by the Square Wave Response Function (SWRF) method whereas NTF was estimated by Noise Power Spectrum (NPS) measurements, under uniform screen irradiation. Our results showed that LSO:Ce exhibits high MTF, which is comparable to that of the commercially used Gd2O2S:Tb powder scintillator. Considering our MTF results and the fast response of LSO:Ce scintillator screen (40 ns), this material can be considered for use in X-ray mammographic detectors. en
heal.publisher Elsevier Science Ltd en
heal.journalName Nuclear Instruments and Methods in Physics Research A en
heal.journalType peer-reviewed
heal.fullTextAvailability true