Εμφάνιση απλής εγγραφής

dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Κάβουρας, Διονύσης Α. el
dc.contributor.author Καλύβας, Νεκτάριος Ι. el
dc.contributor.author Νομικός, Κωνσταντίνος Δ. el
dc.contributor.author Παναγιωτάκης, Γεώργιος Σ. el
dc.date.accessioned 2015-01-20T13:23:35Z
dc.date.available 2015-01-20T13:23:35Z
dc.date.issued 2015-01-20
dc.identifier.uri http://hdl.handle.net/11400/4322
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.elsevier.com en
dc.subject Quantum efficiency
dc.subject X-ray beam
dc.subject Κβαντική απόδοση
dc.subject Δέσμη ακτίνων Χ
dc.title Estimation of the information content of medical images produced by scintillators interacting with diagnostic X-ray beams en
heal.type journalArticle
heal.classification Medicine
heal.classification Physics
heal.classification Ιατρική
heal.classification Φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.identifier.secondary doi:10.1016/S0168-583X(99)00239-6
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 1999
heal.bibliographicCitation Kandarakis, I., Cavouras, D., Kalivas, N., Nomicos, C. and Panayiotakis, G. (July 1999). Estimation of the information content of medical images produced by scintillators interacting with diagnostic X-ray beams. Nuclear Instruments and Methods in Physics Research B. 155(1-2). pp. 199–205. Elsevier Science Ltd. Available from: http://www.sciencedirect.com [Accessed 10/08/1999] en
heal.abstract The information content of medical images produced by X-ray beam–scintillator interaction was assessed by a method involving detective quantum efficiency (DQE) and information capacity determination. The method was based on emitted light fluence and modulation transfer function (MTF) measurements and it was employed to evaluate the performance of (Gd0.5La0.5)2O2S:Tb scintillator, which was used in the form of laboratory prepared scintillator screens with coating weights ranging between 20 and 139 mg/cm2. Screens were excited to luminescence using 80 and 120 kVp X-ray beams. The scintillator layer exhibited the highest DQE at zero spatial frequency. Thick scintillator layers displayed higher DQE values in the low frequency range while at high frequencies the DQE of thin scintillators were higher. Additionally, thin scintillator layers showed slow DQE variation with increasing frequency. The information capacity of scintillator layers decreased with increasing coating weight indicating that the information content of images produced by thin scintillating layers is higher and more evenly distributed with respect to spatial frequencies. en
heal.publisher Elsevier Science Ltd en
heal.journalName Nuclear Instruments and Methods in Physics Research B en
heal.journalType peer-reviewed
heal.fullTextAvailability true