dc.subject Full field digital
dc.subject Radiography, Medical--Digital techniques
dc.subject Πλήρες ψηφιακός τομέας
dc.subject Υπολογιστική ακτινογραφία
dc.title Comparison of full field digital (FFD) and computed radiography (CR) mammography systems in Greece en
heal.type journalArticle
heal.classification Medicine
heal.classification Biomedical engineering
heal.classification Ιατρική
heal.classification Βιοϊατρική τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85014237
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Βιοϊατρική τεχνολογία
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85110695
heal.contributorName Σημαντηράκης, Γεώργιος el
heal.contributorName Μανουσαρίδης, Γ. el
heal.contributorName Καϊσάς, Ι. el
heal.contributorName Καμενοπούλου, Βασιλική el
heal.identifier.secondary doi: 10.1093/rpd/ncr339
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2011
heal.bibliographicCitation Kalathaki, M., Hourdakis, C., Economides, S., Tritakis, P., Kalyvas, N., et al. (August 2011). Comparison of full field digital (FFD) and computed radiography (CR) mammography systems in Greece. Radiation Protection Dosimetry. 147(1-2). pp. 202-205. Oxford University Press. Available from: http://rpd.oxfordjournals.org [Accessed 04/08/2011] en
heal.abstract The purpose of this study is to evaluate and compare the performance of 52 full field digital (FFD) and computed radiography (CR) mammography systems checked by the Greek Atomic Energy Commission with respect to dose and image quality. Entrance surface air kerma (ESAK) was measured and average glandular dose (AGD) was calculated according to the European protocol on dosimetry in mammography. The exposures were performed using the clinical protocol of each laboratory. The image quality was assessed by the total score of resolved phantom structures incorporated in an American College of Radiology accreditation phantom. The mean ESAK values for FFD and CR systems were 4.59±1.93 and 5.0±1.78 mGy, respectively, whereas the AGD yielded a mean value of 1.06±0.36 mGy for the FFD and 1.04±0.35 mGy for the CR systems. Considering image quality, FFD systems indicated a mean total score of 13.04±0.89, whereas CR systems a mean total score of 11.54±1.06. en
heal.publisher Oxford University Press en
heal.journalName Radiation Protection Dosimetry en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες