dc.contributor.author | Καλαθάκη, Μαρία | el |
dc.contributor.author | Χουρδάκης, Κωνσταντίνος | el |
dc.contributor.author | Οικονομίδης, Στέφανος | el |
dc.contributor.author | Τριτάκης, Π. | el |
dc.contributor.author | Καλύβας, Νεκτάριος Ι. | el |
dc.date.accessioned | 2015-01-20T13:58:24Z | |
dc.date.available | 2015-01-20T13:58:24Z | |
dc.date.issued | 2015-01-20 | |
dc.identifier.uri | http://hdl.handle.net/11400/4325 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.oxfordjournals.org/en/ | en |
dc.subject | Full field digital | |
dc.subject | Radiography, Medical--Digital techniques | |
dc.subject | Πλήρες ψηφιακός τομέας | |
dc.subject | Υπολογιστική ακτινογραφία | |
dc.title | Comparison of full field digital (FFD) and computed radiography (CR) mammography systems in Greece | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Biomedical engineering | |
heal.classification | Ιατρική | |
heal.classification | Βιοϊατρική τεχνολογία | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85014237 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Βιοϊατρική τεχνολογία | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85110695 | |
heal.contributorName | Σημαντηράκης, Γεώργιος | el |
heal.contributorName | Μανουσαρίδης, Γ. | el |
heal.contributorName | Καϊσάς, Ι. | el |
heal.contributorName | Καμενοπούλου, Βασιλική | el |
heal.identifier.secondary | doi: 10.1093/rpd/ncr339 | |
heal.language | en | |
heal.access | free | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2011 | |
heal.bibliographicCitation | Kalathaki, M., Hourdakis, C., Economides, S., Tritakis, P., Kalyvas, N., et al. (August 2011). Comparison of full field digital (FFD) and computed radiography (CR) mammography systems in Greece. Radiation Protection Dosimetry. 147(1-2). pp. 202-205. Oxford University Press. Available from: http://rpd.oxfordjournals.org [Accessed 04/08/2011] | en |
heal.abstract | The purpose of this study is to evaluate and compare the performance of 52 full field digital (FFD) and computed radiography (CR) mammography systems checked by the Greek Atomic Energy Commission with respect to dose and image quality. Entrance surface air kerma (ESAK) was measured and average glandular dose (AGD) was calculated according to the European protocol on dosimetry in mammography. The exposures were performed using the clinical protocol of each laboratory. The image quality was assessed by the total score of resolved phantom structures incorporated in an American College of Radiology accreditation phantom. The mean ESAK values for FFD and CR systems were 4.59±1.93 and 5.0±1.78 mGy, respectively, whereas the AGD yielded a mean value of 1.06±0.36 mGy for the FFD and 1.04±0.35 mGy for the CR systems. Considering image quality, FFD systems indicated a mean total score of 13.04±0.89, whereas CR systems a mean total score of 11.54±1.06. | en |
heal.publisher | Oxford University Press | en |
heal.journalName | Radiation Protection Dosimetry | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |