dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Νικολόπουλος, Δημήτριος Σ. | el |
dc.contributor.author | Αναστασίου, Α. | el |
dc.contributor.author | Δημητρόπουλος, Νικόλαος | el |
dc.date.accessioned | 2015-01-20T14:42:24Z | |
dc.date.available | 2015-01-20T14:42:24Z | |
dc.date.issued | 2015-01-20 | |
dc.identifier.uri | http://hdl.handle.net/11400/4329 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.elsevier.com | en |
dc.subject | Phosphor screens | |
dc.subject | Imaging systems--Image quality--Congresses | |
dc.subject | Οθόνες φωσφόρου | |
dc.subject | Ποιότητα εικόνας | |
dc.title | Evaluation of ZnS:Cu phosphor as X-ray to light converter under mammographic conditions | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Physics | |
heal.classification | Ιατρική | |
heal.classification | Φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Φυσική | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh2008123039 | |
heal.contributorName | Καλύβας, Νεκτάριος Ι. | el |
heal.contributorName | Βεντούρας, Ερρίκος Μ. | el |
heal.contributorName | Καλατζής, Ιωάννης | el |
heal.contributorName | Νομικός, Κωνσταντίνος Δ. | el |
heal.contributorName | Παναγιωτάκης, Γεώργιος Σ. | el |
heal.identifier.secondary | doi:10.1016/j.radmeas.2004.02.023 | |
heal.language | en | |
heal.access | free | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2005 | |
heal.bibliographicCitation | Kandarakis, I., Cavouras, D., Nikolopoulos, D., Anastasiou, A., Dimitropoulos, N., et al. (June 2005). Evaluation of ZnS:Cu phosphor as X-ray to light converter under mammographic conditions. Radiation Measurements. 39(3). pp. 263–275. Elsevier Science Ltd. Available from: http://www.sciencedirect.com {Accessed 14/04/2004] | en |
heal.abstract | The aim of the present study was to evaluate ZnS:Cu phosphor for use in X-ray mammographic detectors. This phosphor has never been used in medical imaging probably due to its moderate scintillation decay time. However, it may be suitable for non-dynamic medical imaging, due to its “green” emission spectrum, which is compatible with the sensitivity of many currently used photodetectors, and its high X-ray to light intrinsic conversion efficiency. ZnS:Cu phosphor powder was used to prepare several test screens in laboratory. Parameters related to light emission and image quality properties were experimentally as well as theoretically evaluated and compared to those of other known ZnS-based phosphor materials. Results showed that ZnS:Cu performed adequately well in the mammographic energy range. | en |
heal.publisher | Elsevier Science Ltd | en |
heal.journalName | Radiation Measurements | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: