Εμφάνιση απλής εγγραφής

dc.contributor.author Καλύβας, Νεκτάριος Ι. el
dc.contributor.author Δήμου, Άννα el
dc.contributor.author Τσινούκας, Κώστας el
dc.contributor.author Φούντος, Γεώργιος Π. el
dc.contributor.author Μιχαήλ, Χρήστος Μ. el
dc.date.accessioned 2015-01-21T10:46:35Z
dc.date.available 2015-01-21T10:46:35Z
dc.date.issued 2015-01-21
dc.identifier.uri http://hdl.handle.net/11400/4418
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source [χ.ό.] el
dc.subject Film digitization
dc.subject Contrast detail
dc.subject Φιλμ ψηφιοποίησης
dc.subject Λεπτομέρεια αντίθεσης
dc.title Effect of film digitization on mammographic image quality en
heal.type journalArticle
heal.generalDescription Workshop on Bio-Medical Instrumentation and related Engineering And Physical Sciences en
heal.classification Medicine
heal.classification Medical technology
heal.classification Ιατρική
heal.classification Ιατρική τεχνολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://skos.um.es/unescothes/C02465
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ιατρική τεχνολογία
heal.contributorName Βαλαής, Ιωάννης Σ. el
heal.contributorName Κανδαράκης, Ιωάννης Σ. el
heal.identifier.secondary ISSN 17905613
heal.language en
heal.access free
heal.recordProvider Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. el
heal.publicationDate 2012
heal.bibliographicCitation Kalyvas, N., Dimou, A., Tsinoukas, K., Fountos, G., Michail, C., et al. (2012). Effect of film digitization on mammographic image quality. e-Journal of Science & Technology. 7(3). pp. 23-28. Available from: http://e-jst.teiath.gr en
heal.abstract The modern hospital environment uses PACS (Picture Archiving and Communication System) instrumentation for storing and process digital images. Breast cancer is of the highest causes for women death. Routinely mammography examinations are performed for the early detection of breast cancer and reference purposes. The purpose of this study was to evaluate the image quality of digitized films which might be incorporated in digital hospital environment. The Artinis CDMAM type 3.4 phantom, was placed in contact with 40mm PMMA slabs and irradiated with Mo/Mo and Mo/Rh typical X-ray mammographic spectra. The derived films were digitized with an AGFA Duo Scan medical scanner with 8bit pixel depth and 1000ppi resolution. The optical density of the film was in the linear pat of the scanner transfer curve. For the analysis of the digitized images the Image J software was used. The contrast detail curve to both the analog and the digitized films was calculated according to the CDMAM instructions. It was found that the 25kV mammogram was presented betted contrast detail than the other exposure conditions. If the 28kV is consider the image quality of the film depends upon the position of the phantom with respect to the film. In most cases the digitized film presents worse contrast detail. en
heal.publisher [χ.ό.] el
heal.journalName e-Journal of Science & Technology en
heal.journalName e-Περιοδικό Επιστήμης & Τεχνολογίας el
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες