dc.contributor.author | Βαλαής, Ιωάννης Γ. | el |
dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Νικολόπουλος, Δημήτριος | el |
dc.contributor.author | Σιανούδης, Ιωάννης Α. | el |
dc.contributor.author | Δημητρόπουλος, Νικόλαος | el |
dc.date.accessioned | 2015-01-23T12:50:51Z | |
dc.date.available | 2015-01-23T12:50:51Z | |
dc.date.issued | 2015-01-23 | |
dc.identifier.uri | http://hdl.handle.net/11400/4605 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | X-ray imaging | |
dc.subject | Biomedical materials--Imaging compatibility | |
dc.subject | Απεικόνιση με ακτίνες Χ | |
dc.subject | Βιοϊατρική απεικόνιση | |
dc.title | Luminescence efficiency of Gd2SiO5:Ce scintillator under X-ray excitation | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Physics | |
heal.classification | Ιατρική | |
heal.classification | Φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Φυσική | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh2002010215 | |
heal.contributorName | Κάβουρας, Διονύσης Α. | el |
heal.contributorName | Νομικός, Κωνσταντίνος Δ. | el |
heal.contributorName | Παναγιωτάκης, Γεώργιος Σ. | el |
heal.identifier.secondary | DOI: 10.1109/TNS.2005.856895 | |
heal.identifier.secondary | ISSN : 0018-9499 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2005 | |
heal.bibliographicCitation | Valais, I., Kandarakis, I., Nikolopoulos, D., Sianoudis, I., Dimitropoulos, N., et al. (October 2005). Luminescence efficiency of Gd2SiO5:Ce scintillator under X-ray excitation. Transactions on Nuclear Science. 52(5). pp. 1830 - 1835. IEEE. | en |
heal.abstract | Gd2SiO5:Ce (GSO:Ce) is a high-Z, nonhygroscopic fast emitting scintillator used in detectors of positron emission tomography (PET) systems. The purpose of this study was to evaluate the luminescence efficiency of GSO:Ce scintillator under irradiation conditions employed in X-ray medical imaging, since findings may be of value in novel applications such as computed tomography breast imaging or modern fast image producing X-ray computed tomography. To this aim the absolute luminescence efficiency (emitted light flux over X-ray exposure), the spectral matching factor (compatibility to optical detectors), and the effective efficiency (the product of absolute efficiency and spectral compatibility) were determined for X-ray tube voltages ranging from 20 to 140 kV. The efficiency of GSO:Ce was found to increase with increasing X-ray tube voltage, while the GSO:Ce spectrum, peaking at 440 and 490 nm, was found compatible to most optical detectors (photodiodes, photocathodes, and charge-coupled devices). | en |
heal.sponsor | IEEE Nuclear and Plasma Sciences Society | en |
heal.publisher | IEEE | en |
heal.journalName | Transactions on Nuclear Science | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: