Εμφάνιση απλής εγγραφής

dc.contributor.author Βαλαής, Ιωάννης Γ. el
dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.contributor.author Νικολόπουλος, Δημήτριος Ν. el
dc.contributor.author Σιανούδης, Ιωάννης Α. el
dc.contributor.author Δημητρόπουλος, Νικόλαος el
dc.date.accessioned 2015-01-24T15:42:07Z
dc.date.available 2015-01-24T15:42:07Z
dc.date.issued 2015-01-24
dc.identifier.uri http://hdl.handle.net/11400/4668
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://e-jst.teiath.gr/ en
dc.subject Tomography
dc.subject Τομογραφία
dc.subject Low energy gamma ray imaging
dc.subject Απεικόνιση χαμηλής ενέργειας ακτίνων γάμμα
dc.subject Photomultiplier
dc.subject Φωτοπολλαπλασιαστής
dc.title Luminescence efficiency of (Gd2SiO5:Ce) scintillator under x-ray excitation en
heal.type journalArticle
heal.classification Science
heal.classification Επιστήμες
heal.classification Physics
heal.classification Φυσική
heal.classificationURI http://zbw.eu/stw/descriptor/15685-2
heal.classificationURI **N/A**-Επιστήμες
heal.classificationURI http://zbw.eu/stw/descriptor/15669-0
heal.classificationURI **N/A**-Φυσική
heal.contributorName Κάβουρας, Διονύσης Α. el
heal.contributorName Παναγιωτάκης, Γεώργιος Σ. el
heal.language en
heal.access free
heal.recordProvider el
heal.publicationDate 2006
heal.bibliographicCitation Valais, I.G., Kandarakis, I.S., Nikolopoulos, D.N., Sianoudis, I.A., Dimitropoulos, N., et al (2006). Luminescence efficiency of (Gd2SiO5:Ce) scintillator under x-ray excitation. "e-Journal of Science & Technology". [Online] 1(1): 35-42. Available from: http://e-jst.teiath.gr/ en
heal.abstract Gd2SiO5:Ce (GSO:Ce) is a high-Z, nonhygroscopic fast emitting scintillator used in detectors of some positron tomography systems. The purpose of this study was to evaluate the luminescence of GSO:Ce scintillator at lower photon energies employed in other fields of medical imaging (e.g. x-ray computed tomography, general x-ray imaging, low energy gamma ray imaging). To this aim the absolute luminescence efficiency (emitted light flux over x-ray exposure), the matching factor (spectral compatibility to optical detectors) and the effective efficiency (combination of absolute efficiency with spectral compatibility) were experimentally determined. Various xray tube voltages ranging from 20 to 140 kV (employed in xray mammography, general radiography, and computed tomography) were used. In addition the behaviour of GSO: Ce under low energy gamma irradiation could be estimated from these data. Measurements were performed using an experimental set-up based on a photomultiplier coupled to an integration sphere. The GSO:Ce optical emission spectrum was measured under x-ray excitation using an optical grating monochromator. The efficiency of GSO:Ce was found to increase with increasing x-ray tube voltage, while the GSO:Ce spectrum, peaking at 440 and 490 nm, was found compatible with most optical detectors (photodiodes, photocathodes, charge coupled devices). However the spectral compatibility (0.77) and the effective efficiency were found highest for GSO coupled to photodiode. en
heal.publisher Νερατζής, Ηλίας el
heal.publisher Σιανούδης, Ιωάννης el
heal.journalName e-Journal of Science & Technology en
heal.journalName e-Περιοδικό Επιστήμης & Τεχνολογίας el
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες