dc.contributor.author | McCamis, R. H. | en |
dc.contributor.author | Verheijen, W. T. H. | en |
dc.contributor.author | Van Oers, Pinner Roeland | en |
dc.contributor.author | Δρακόπουλος, Πάνος | el |
dc.contributor.author | Lapointe, Clinton | en |
dc.date.accessioned | 2015-01-26T10:54:16Z | |
dc.date.available | 2015-01-26T10:54:16Z | |
dc.date.issued | 2015-01-26 | |
dc.identifier.uri | http://hdl.handle.net/11400/4756 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | Physical optics | |
dc.subject | Electric discharge lighting | |
dc.subject | Φυσική Οπτική | |
dc.subject | Ηλεκτρικός φωτιστμός εκκένωσης | |
dc.title | He(p,p) He analyzing powers between 25 and 35 MeV | en |
heal.type | journalArticle | |
heal.classification | Ophthalmology | |
heal.classification | Optics | |
heal.classification | Οφθαλμολογία | |
heal.classification | Οπτική | |
heal.classificationURI | http://skos.um.es/unescothes/C02842 | |
heal.classificationURI | http://skos.um.es/unescothes/C02847 | |
heal.classificationURI | **N/A**-Οφθαλμολογία | |
heal.classificationURI | **N/A**-Οπτική | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85095187 | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85041653 | |
heal.contributorName | Maughan, G. R. | en |
heal.contributorName | Okumusoglu, N. T. | en |
heal.contributorName | Brown, Ronald E. | en |
heal.identifier.secondary | DOI: http://dx.doi.org/10.1103/PhysRevC.31.1651 | |
heal.language | en | |
heal.access | campus | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας, Σχολή Επαγγελμάτων Υγείας & Πρόνοιας, Τμήμα Οπτικής & Οπτομετρίας | el |
heal.publicationDate | 1985-05-01 | |
heal.bibliographicCitation | McCamis, R.H., Verheijen, P.J.T., van Oers, W.T.H., Drakopoulos, P., Lapointe, C., et.al. (1985). He(p,p) He analyzing powers between 25 and 35 MeV . Physical Review C 31(5), 1/05/1985, pp. 1651. Available from: https://app.box.com/files/0/f/2193377207/1/f_25029212331 | en |
heal.abstract | A polarized He3 target, which uses conventional optical pumping with He4 discharge lamps, has been used for the measurement of He3 analyzing powers Ay(θ) at energies of 25.0, 30.0, 32.5, and 35.0 MeV. The statistical uncertainties in the data are on the order of 0.03; the systematic uncertainty is estimated to be 0.05. These data are compared with fits and predictions from various phase shift analyses. | en |
heal.journalName | Physical Review C | el |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true | |
heal.dateCreated | 1985-01-28 |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: