dc.contributor.author | Παπανικολάου, Νικόλαος | el |
dc.contributor.author | Καραντάνας, Απόστολος | el |
dc.contributor.author | Λαβδάς, Ελευθέριος | el |
dc.date.accessioned | 2015-01-26T20:10:00Z | |
dc.date.issued | 2015-01-26 | |
dc.identifier.uri | http://hdl.handle.net/11400/4797 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://online.sagepub.com/ | en |
dc.subject | Magnetic resonance imaging | |
dc.subject | Comparison of sequences | |
dc.subject | Μαγνητική τομογραφία | |
dc.subject | Ήπαρ | |
dc.subject | Σύγκριση ακολουθιών | |
dc.subject | Liver | |
dc.title | MR Imaging of the liver using an ultralast 3d multi shot EPI sequence | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Radiology, Medical | |
heal.classification | Ιατρική | |
heal.classification | Ακτινολογία, Ιατρική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85110777 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Ακτινολογία, Ιατρική | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85079741 | |
heal.identifier.secondary | DOI: 10.3109/02841859909175561 | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.recordProvider | Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας.Σχολή Επαγγελμάτων Υγείας και Πρόνοιας.Τμήμα Ραδιολογίας και Ακτινολογίας. | el |
heal.publicationDate | 1999-05 | |
heal.bibliographicCitation | Papanikolaou, N., Karantanas, N. and Lavdas, E. (1999). MR Imaging of the Liver using an ultralast 3d Multi shot EPI seguence. "Acta Radiologica" 40 (3), p.322-325. | en |
heal.abstract | Purpose: To compare a 3D echo planar imaging (EPI) sequence with four other T1-weighted sequences for imaging of the liver at 1 T. Material and Methods: Twenty volunteers were included in our imaging protocol. Spin-echo (SE), turbo SE (TSE), turbo field echo (TFE) in 2D and 3D acquisition mode, fast field echo (T1-FFE) and 3D EPI sequences were applied. Signal-to-noise (S/N) ratio of the liver, contrast-to-noise (C/N) ratio and relative contrast (ReCon) between the liver and the spleen, scanning time per slice and artifact levels were evaluated. Results: 3D EPI provided a statistically equivalent S/N ratio of the liver with SE and T1-FFE sequences (p > 0.05), while it provided a statistically higher S/N ratio of the liver compared to TFE sequences (p < 0.05). The TSE technique provided a statistically higher S/N ratio of the liver compared to 3D EPI (p < 0.05). With regard to the liver-spleen C/N ratio, 3D EPI provided statistically equivalent results compared to all sequences except T1-FFE, where 3D EPI was superior. With regard to liver-spleen ReCon, 3D EPI was statistically equivalent to SE, TSE and T1-FFE, while it provided significantly higher liver-spleen ReCon than 3D TFE and significantly lower than 2D TFE. Conclusion: 3D EPI provided sufficient ReCon and C/N ratio and produced motion-free images in one breath-hold period. Further clinical studies are required to estimate the sensitivity, specificity and accuracy of the sequence. | en |
heal.publisher | SAGE Publications | en |
heal.journalName | Acta Radiologica | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | false |
Αρχεία | Μέγεθος | Μορφότυπο | Προβολή |
---|---|---|---|
Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο. |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: