Show simple item record

dc.contributor.author Παπανικολάου, Νικόλαος el
dc.contributor.author Καραντάνας, Απόστολος el
dc.contributor.author Λαβδάς, Ελευθέριος el
dc.date.accessioned 2015-01-26T20:10:00Z
dc.date.issued 2015-01-26
dc.identifier.uri http://hdl.handle.net/11400/4797
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://online.sagepub.com/ en
dc.subject Magnetic resonance imaging
dc.subject Comparison of sequences
dc.subject Μαγνητική τομογραφία
dc.subject Ήπαρ
dc.subject Σύγκριση ακολουθιών
dc.subject Liver
dc.title MR Imaging of the liver using an ultralast 3d multi shot EPI sequence en
heal.type journalArticle
heal.classification Medicine
heal.classification Radiology, Medical
heal.classification Ιατρική
heal.classification Ακτινολογία, Ιατρική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85110777
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ακτινολογία, Ιατρική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85079741
heal.identifier.secondary DOI: 10.3109/02841859909175561
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας.Σχολή Επαγγελμάτων Υγείας και Πρόνοιας.Τμήμα Ραδιολογίας και Ακτινολογίας. el
heal.publicationDate 1999-05
heal.bibliographicCitation Papanikolaou, N., Karantanas, N. and Lavdas, E. (1999). MR Imaging of the Liver using an ultralast 3d Multi shot EPI seguence. "Acta Radiologica" 40 (3), p.322-325. en
heal.abstract Purpose: To compare a 3D echo planar imaging (EPI) sequence with four other T1-weighted sequences for imaging of the liver at 1 T. Material and Methods: Twenty volunteers were included in our imaging protocol. Spin-echo (SE), turbo SE (TSE), turbo field echo (TFE) in 2D and 3D acquisition mode, fast field echo (T1-FFE) and 3D EPI sequences were applied. Signal-to-noise (S/N) ratio of the liver, contrast-to-noise (C/N) ratio and relative contrast (ReCon) between the liver and the spleen, scanning time per slice and artifact levels were evaluated. Results: 3D EPI provided a statistically equivalent S/N ratio of the liver with SE and T1-FFE sequences (p > 0.05), while it provided a statistically higher S/N ratio of the liver compared to TFE sequences (p < 0.05). The TSE technique provided a statistically higher S/N ratio of the liver compared to 3D EPI (p < 0.05). With regard to the liver-spleen C/N ratio, 3D EPI provided statistically equivalent results compared to all sequences except T1-FFE, where 3D EPI was superior. With regard to liver-spleen ReCon, 3D EPI was statistically equivalent to SE, TSE and T1-FFE, while it provided significantly higher liver-spleen ReCon than 3D TFE and significantly lower than 2D TFE. Conclusion: 3D EPI provided sufficient ReCon and C/N ratio and produced motion-free images in one breath-hold period. Further clinical studies are required to estimate the sensitivity, specificity and accuracy of the sequence. en
heal.publisher SAGE Publications en
heal.journalName Acta Radiologica en
heal.journalType peer-reviewed
heal.fullTextAvailability false


Files in this item

Files Size Format View

There are no files associated with this item.

The following license files are associated with this item:

Show simple item record

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Except where otherwise noted, this item's license is described as Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες