dc.title MR Imaging of the liver using an ultralast 3d multi shot EPI sequence en
heal.type journalArticle
heal.classification Medicine
heal.classification Radiology, Medical
heal.classification Ιατρική
heal.classification Ακτινολογία, Ιατρική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85110777
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ακτινολογία, Ιατρική
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85079741
heal.identifier.secondary DOI: 10.3109/02841859909175561
heal.dateAvailable 10000-01-01
heal.language en
heal.access forever
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας.Σχολή Επαγγελμάτων Υγείας και Πρόνοιας.Τμήμα Ραδιολογίας και Ακτινολογίας. el
heal.publicationDate 1999-05
heal.bibliographicCitation Papanikolaou, N., Karantanas, N. and Lavdas, E. (1999). MR Imaging of the Liver using an ultralast 3d Multi shot EPI seguence. "Acta Radiologica" 40 (3), p.322-325. en
heal.abstract Purpose: To compare a 3D echo planar imaging (EPI) sequence with four other T1-weighted sequences for imaging of the liver at 1 T. Material and Methods: Twenty volunteers were included in our imaging protocol. Spin-echo (SE), turbo SE (TSE), turbo field echo (TFE) in 2D and 3D acquisition mode, fast field echo (T1-FFE) and 3D EPI sequences were applied. Signal-to-noise (S/N) ratio of the liver, contrast-to-noise (C/N) ratio and relative contrast (ReCon) between the liver and the spleen, scanning time per slice and artifact levels were evaluated. Results: 3D EPI provided a statistically equivalent S/N ratio of the liver with SE and T1-FFE sequences (p > 0.05), while it provided a statistically higher S/N ratio of the liver compared to TFE sequences (p < 0.05). The TSE technique provided a statistically higher S/N ratio of the liver compared to 3D EPI (p < 0.05). With regard to the liver-spleen C/N ratio, 3D EPI provided statistically equivalent results compared to all sequences except T1-FFE, where 3D EPI was superior. With regard to liver-spleen ReCon, 3D EPI was statistically equivalent to SE, TSE and T1-FFE, while it provided significantly higher liver-spleen ReCon than 3D TFE and significantly lower than 2D TFE. Conclusion: 3D EPI provided sufficient ReCon and C/N ratio and produced motion-free images in one breath-hold period. Further clinical studies are required to estimate the sensitivity, specificity and accuracy of the sequence. en
heal.publisher SAGE Publications en
heal.journalName Acta Radiologica en
heal.journalType peer-reviewed
heal.fullTextAvailability false


Αρχεία σε αυτό το τεκμήριο

Αρχεία Μέγεθος Μορφότυπο Προβολή

Δεν υπάρχουν αρχεία που σχετίζονται με αυτό το τεκμήριο.

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες