Εμφάνιση απλής εγγραφής

dc.contributor.author Σπυροπούλου, Βασιλική Α. el
dc.contributor.author Καλύβας, Νεκτάριος Ι. el
dc.contributor.author Γαϊτάνης, Αναστάσιος el
dc.contributor.author Μιχαήλ, Χρήστος Μ. el
dc.contributor.author Παναγιωτάκης, Γεώργιος Σ. el
dc.date.accessioned 2015-01-27T09:15:12Z
dc.date.available 2015-01-27T09:15:12Z
dc.date.issued 2015-01-27
dc.identifier.uri http://hdl.handle.net/11400/4820
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://e-jst.teiath.gr/ en
dc.subject Image quality
dc.subject Ποιότητα εικόνας
dc.subject Digital mammography
dc.subject Linear cascaded systems theory
dc.subject Indirect detectors
dc.subject Ψηφιακή μαστογραφία
dc.subject Θεωρία γραμμικής κλιμάκωσης συστημάτων
dc.subject Έμμεσοι ανιχνευτές
dc.title Modeling detector performance in digital mammography using the linear cascaded systems approach en
dc.title Μοντελοποίηση της απόδοσης ανιχνευτή ψηφιακής μαστογραφίας μέσω της θεωρίας γραμμικών αλληλοδιαδοχικών συστημάτων el
heal.type journalArticle
heal.classification Medicine
heal.classification Medical physics
heal.classification Ιατρική φυσική
heal.classification Ιατρική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85083001
heal.classificationURI **N/A**-Ιατρική φυσική
heal.classificationURI **N/A**-Ιατρική
heal.contributorName Κανδαράκης, Ιωάννης Σ. el
heal.language en
heal.access free
heal.publicationDate 2008
heal.bibliographicCitation Spyropoulou, V. A., Kalivas, N. I., Gaitanis, A., Michail, C. M., Panayiotakis, G. S., et al. (2008) Modeling detector performance in digital mammography using the linear cascaded systems approach. "e-Journal of Science & Technology". [Online] 3 (2). p. 52-57. Available from: http://e-jst.teiath.gr/ [Accessed 27/01/2015] el
heal.abstract Digital x-ray mammography is a modern method for the early detection of breast cancer. The quality of a mammography image depends on various factors, the detector structure and performance being of primary importance. The aim of this work was to develop an analytical model simulating the imaging performance of a new commercially available digital mammography detector. This was achieved within the framework of the linear cascaded systems (LCS) theory. System analysis has allowed the estimation of important image quality metrics such as the Modulation Transfer Function (MTF), the Noise Power Spectrum (NPS), the Detective Quantum Efficiency (DQE) and the Signal to Noise Ratio (SNR). The detector was an indirect detection system consisting of a large area, 100μm thick, CsI:TI scintillator coupled to an active matrix array of amorphous silicon (a-Si:H) photodiodes combined with thin film transistors (TFT). Pixel size was 100μm, while the active pixel dimension was 70μm. MTF and DQE data were calculated for air kerma conditions of 25, 53, 67 μGy using a 28 kVp Mo-Mo x-ray spectrum. In addition, the scintillator thickness was changed in order to find the optimum material characteristics. The theoretical results were compared with published experimental data. The deviation between the theoretical and experimental MTF curves was less than 4%, while the DQE differences were found at an acceptable level. en
heal.publisher Νερατζής, Ηλίας el
heal.publisher Σιανούδης, Ιωάννης el
heal.journalName e-Journal of Science & Technology en
heal.journalName e-Περιοδικό Επιστήμης & Τεχνολογίας el
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες