Εμφάνιση απλής εγγραφής

dc.contributor.author Τουτουντζής, Ανδριανός Ε. el
dc.contributor.author Σταθόνικος, Νικόλαος el
dc.contributor.author Φούντος, Γεώργιος Π. el
dc.contributor.author Νικηφορίδης, Γεώργιος Χ. el
dc.contributor.author Κανδαράκης, Ιωάννης Σ. el
dc.date.accessioned 2015-01-27T10:34:01Z
dc.date.available 2015-01-27T10:34:01Z
dc.date.issued 2015-01-27
dc.identifier.uri http://hdl.handle.net/11400/4834
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://e-jst.teiath.gr/ en
dc.subject Noise
dc.subject Θόρυβος
dc.subject Dual energy
dc.subject Mammography
dc.subject SNR
dc.subject GdOS
dc.subject LSO
dc.subject Διπλή ενέργεια
dc.subject Μαστογραφία
dc.title Dual energy mammography en
heal.type journalArticle
heal.secondaryTitle evaluation of scintillators for X-ray detectors using a signal to noise ratio model en
heal.classification Medicine
heal.classification Medical physics
heal.classification Ιατρική
heal.classification Ιατρική φυσική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85083001
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Ιατρική φυσική
heal.language en
heal.access free
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Tμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας el
heal.publicationDate 2009
heal.bibliographicCitation Toutountzis, A. E., Stathonikos, N., Fountos, G. P., Nikiforidis, G. C. & Kandarakis. I.S. (2009) Dual energy mammography: evaluation of scintillators for X-ray detectors using a signal to noise ratio model. "e-Journal of Science & Technology". [Online] 4 (1). p. 1-9. Available from: http://e-jst.teiath.gr/ [Accessed 27/01/2015] en
heal.abstract The purpose of this study was to perform an analysis on microcalcification visualization in dual energy subtraction mammography. A theoretical model was applied in order to evaluate the signal to noise ratio on subtracted mammographic images. The detector performance is investigated and compared for two different scintillators; the commercially used GdOS:Tb, and LSO:Ce. In addition, the estimation of signal and noise levels is performed for different tissue compositions and various x ray spectra. The image parameters were selected for the optimization of a dual energy subtraction technique for the improved detection and visualization of microcalcifications. The results are presented and the dependence on image parameters is discussed. en
heal.publisher Νερατζής, Ηλίας el
heal.publisher Σιανούδης, Ιωάννης el
heal.journalName e-Journal of Science & Technology en
heal.journalName e-Περιοδικό Επιστήμης & Τεχνολογίας el
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες