dc.contributor.author | Τουτουντζής, Ανδριανός Ε. | el |
dc.contributor.author | Σταθόνικος, Νικόλαος | el |
dc.contributor.author | Φούντος, Γεώργιος Π. | el |
dc.contributor.author | Νικηφορίδης, Γεώργιος Χ. | el |
dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.date.accessioned | 2015-01-27T10:34:01Z | |
dc.date.available | 2015-01-27T10:34:01Z | |
dc.date.issued | 2015-01-27 | |
dc.identifier.uri | http://hdl.handle.net/11400/4834 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://e-jst.teiath.gr/ | en |
dc.subject | Noise | |
dc.subject | Θόρυβος | |
dc.subject | Dual energy | |
dc.subject | Mammography | |
dc.subject | SNR | |
dc.subject | GdOS | |
dc.subject | LSO | |
dc.subject | Διπλή ενέργεια | |
dc.subject | Μαστογραφία | |
dc.title | Dual energy mammography | en |
heal.type | journalArticle | |
heal.secondaryTitle | evaluation of scintillators for X-ray detectors using a signal to noise ratio model | en |
heal.classification | Medicine | |
heal.classification | Medical physics | |
heal.classification | Ιατρική | |
heal.classification | Ιατρική φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85083001 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Ιατρική φυσική | |
heal.language | en | |
heal.access | free | |
heal.recordProvider | Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Tμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας | el |
heal.publicationDate | 2009 | |
heal.bibliographicCitation | Toutountzis, A. E., Stathonikos, N., Fountos, G. P., Nikiforidis, G. C. & Kandarakis. I.S. (2009) Dual energy mammography: evaluation of scintillators for X-ray detectors using a signal to noise ratio model. "e-Journal of Science & Technology". [Online] 4 (1). p. 1-9. Available from: http://e-jst.teiath.gr/ [Accessed 27/01/2015] | en |
heal.abstract | The purpose of this study was to perform an analysis on microcalcification visualization in dual energy subtraction mammography. A theoretical model was applied in order to evaluate the signal to noise ratio on subtracted mammographic images. The detector performance is investigated and compared for two different scintillators; the commercially used GdOS:Tb, and LSO:Ce. In addition, the estimation of signal and noise levels is performed for different tissue compositions and various x ray spectra. The image parameters were selected for the optimization of a dual energy subtraction technique for the improved detection and visualization of microcalcifications. The results are presented and the dependence on image parameters is discussed. | en |
heal.publisher | Νερατζής, Ηλίας | el |
heal.publisher | Σιανούδης, Ιωάννης | el |
heal.journalName | e-Journal of Science & Technology | en |
heal.journalName | e-Περιοδικό Επιστήμης & Τεχνολογίας | el |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: