Εμφάνιση απλής εγγραφής

dc.contributor.author Φούντος, Γεώργιος Π. el
dc.contributor.author Ζαγκλής, Α. el
dc.contributor.author Μιχαήλ, Χρήστος Μ. el
dc.contributor.author Καλατζής, Ιωάννης el
dc.contributor.author Σαμαρτζής, Α. el
dc.date.accessioned 2015-01-30T16:17:21Z
dc.date.available 2015-01-30T16:17:21Z
dc.date.issued 2015-01-30
dc.identifier.uri http://hdl.handle.net/11400/5154
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://e-jst.teiath.gr/ en
dc.subject Film
dc.subject Ταινία
dc.subject SPECT
dc.subject 99mTc(III)-DMSA
dc.subject MTF
dc.subject LSF
dc.subject Flood source
dc.title A novel flood source used for the MTF determination in SPECT systems en
heal.type journalArticle
heal.generalDescription Special issue: Scientific papers presented on the 3nd International Conference on Experiments/Process/System Modeling/Simulation & Optimization in Athens, 8-11 July, 2009. Mini symposium on Medical Imaging, organized by G. Panayiotakis, I. Kandarakis, G. Fountos and I. Valais en
heal.classification Science
heal.classification Physics
heal.classification Επιστήμες
heal.classification Φυσική
heal.classificationURI http://zbw.eu/stw/descriptor/15685-2
heal.classificationURI http://zbw.eu/stw/descriptor/15669-0
heal.classificationURI **N/A**-Επιστήμες
heal.classificationURI **N/A**-Φυσική
heal.contributorName Κάβουρας, Διονύσης Α. el
heal.contributorName Κουνάδη, Ε. el
heal.contributorName Βαλσαμάκη, Π. el
heal.contributorName Κανδαράκης, Ιωάννης Σ. el
heal.contributorName Γεραλή, Σ. el
heal.contributorName Νικηφορίδης, Γεώργιος Χ. el
heal.language en
heal.access free
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Tμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας el
heal.publicationDate 2010
heal.bibliographicCitation Fountos, G.P., Zanglis, A., Michail, C.M., Kalatzis, I., Samartzis, A., et al. (2010). A novel flood source used for the MTF determination in SPECT systems. "e-Journal of Science & Technology". [Online] 5(2): 1-6. Available from: http://e-jst.teiath.gr/ en
heal.abstract The Modulation Transfer Function (MTF) is an important parameter for the characterization of the signal transfer properties and image quality of a single photon emission computed tomography (SPECT) system. MTF can be derived by determining the line spread function (LSF) from images of a flood source. The method presented here is novel and easy to implement, requires materials commonly found in clinical practice, is robust to aliasing. Furthermore, since this technique is based on the LSF method, reduces measurement noise levels due to greater data averaging than conventional Point Spread Function (PSF)-integration techniques. In an effort to prepare easily, cheaply and reproducibly a Tc-99m-based flood source (Eγ=140 keV), various combinations of films and radiopharmaceuticals were tried. Excellent results were obtained by immersing an Agfa MammoRay HDR Medical X-ray film in a solution of dithiothreitol (DTT, 10-3 M)/Tc-99m(III)-DMSA (DMSA:Trivalent Technetium-99m-dimercapto-succinic acid, 40 mCi/40 mL) for 30-45 min in the dark. These films exhibited high integral uniformity (CV <1.9%). All imaging experiments were performed in a Siemens e-Cam γ-camera. en
heal.publisher Νερατζής, Ηλίας el
heal.publisher Σιανούδης, Ιωάννης el
heal.publisher Βαλαής, Ιωάννης Γ. el
heal.publisher Φούντος, Γεώργιος Π. el
heal.journalName e-Journal of Science & Technology en
heal.journalName e-Περιοδικό Επιστήμης & Τεχνολογίας el
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής