dc.contributor.author | Srivastava, V. P. | en |
dc.contributor.author | Vishnoi, Rochana | en |
dc.contributor.author | Mishra, Shailesh | en |
dc.contributor.author | Sinha, Poonam | en |
dc.date.accessioned | 2015-01-30T20:34:03Z | |
dc.date.available | 2015-01-30T20:34:03Z | |
dc.date.issued | 2015-01-30 | |
dc.identifier.uri | http://hdl.handle.net/11400/5196 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://e-jst.teiath.gr/ | en |
dc.subject | Stenotic region | |
dc.subject | Στενωτική περιοχή | |
dc.subject | Impedance | |
dc.subject | Catheter | |
dc.subject | Αντίσταση | |
dc.subject | Shear stress | |
dc.subject | Καθετήρας | |
dc.subject | Throat | |
dc.subject | Διατμητική τάση | |
dc.subject | Stenotic region | |
dc.subject | Λαιμός | |
dc.subject | Στενωτική περιοχή | |
dc.title | Blood flow through a composite stenosis in catheterized arteries | en |
heal.type | journalArticle | |
heal.classification | Medicine | |
heal.classification | Medical physics | |
heal.classification | Ιατρική | |
heal.classification | Ιατρική φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85083001 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Ιατρική φυσική | |
heal.language | en | |
heal.access | free | |
heal.publicationDate | 2010 | |
heal.bibliographicCitation | Srivastava, V.P., Vishnoi, R., Mishra, S. and Sinha, P. (2010). Blood flow through a composite stenosis in catheterized arteries. "e-Journal of Science & Technology". [Online] 5(4): 55-64. Available from: http://e-jst.teiath.gr/ | en |
heal.abstract | The Problem of blood flow through a composite stenosis during artery catheterization assuming blood to behave like a Newtonian fluid, has been investigated. The analytical expression for the blood flow characteristics, namely, the impedance, the wall shear stress in the stenotic region and the shear stress at stenosis throat has been derived. The impedance increases with the catheter as well as with the stenosis size (height and length both). The wall shear stress in the stenotic region increases in the up stream of the stenosis throat but decreases in the down stream of the throat and achieves to its approached value at a critical axial distance. The magnitude of the wall shear stress at the end point of the constriction profile is much lower than its approached value. The shear stress at the stenosis throat possesses the characteristics similar to that of the flow resistance with respect to any given parameter. | en |
heal.publisher | Νερατζής, Ηλίας | el |
heal.publisher | Σιανούδης, Ιωάννης | el |
heal.journalName | e-Journal of Science & Technology | en |
heal.journalName | e-Περιοδικό Επιστήμης & Τεχνολογίας | el |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |