dc.contributor.author | Κανδαράκης, Ιωάννης Σ. | el |
dc.contributor.author | Κάβουρας, Διονύσης Α. | el |
dc.contributor.author | Βεντούρας, Ερρίκος Μ. | el |
dc.contributor.author | Νομικός, Κωνσταντίνος Δ. | el |
dc.date.accessioned | 2015-02-02T11:10:40Z | |
dc.date.issued | 2015-02-02 | |
dc.identifier.uri | http://hdl.handle.net/11400/5467 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | X-ray imaging | |
dc.subject | Scintillators | |
dc.subject | Απεικόνιση με ακτίνες Χ | |
dc.subject | Σπινθηριστές | |
dc.title | Theoretical evaluation of granular scintillators quantum gain incorporating the effect of K-fluorescence emission into the energy range from 25 to 100 keV | en |
heal.type | journalArticle | |
heal.classification | Physics | |
heal.classification | Quantum field theory | |
heal.classification | Φυσική | |
heal.classification | Θεωρία των κβάντα | |
heal.classificationURI | http://skos.um.es/unescothes/C02994 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85109461 | |
heal.classificationURI | **N/A**-Φυσική | |
heal.classificationURI | **N/A**-Θεωρία των κβάντα | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85118713 | |
heal.identifier.secondary | PII: S 0969-806X(02)00473-5 | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2003 | |
heal.bibliographicCitation | Kandarakis, I., Cavouras, D., Ventouras, E. and Nomicos, C. (2003). Theoretical evaluation of granular scintillators quantum gain incorporating the effect of K-fluorescence emission into the energy range from 25 to 100 keV. Radiation Physics and Chemistry. vol. 66. pp.257-267. Elsevier Science Ltd. | en |
heal.abstract | A theoretical study on optical quantum gain of granular scintillators used in detectors of medical imaging systems is presented. The fraction of optical gain due to K-characteristic radiation was also determined. The study was applied on two widely known scintillating materials, Gd2O2S:Tb and ZnSCdS:Ag, for various incident photon energies and scintillator coating thickness. Optical quantum gain due to K-characteristic photons varies with incident photon energy and scintillator coating thickness and may amount to up to 20% or 29% for Gd2O2S:Tb and ZnSCdS:Ag respectively | en |
heal.publisher | Elsevier Science Ltd | en |
heal.journalName | Radiation Physics and Chemistry | en |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: