dc.contributor.author | Σεφέρης, Ιωάννης Ε. | el |
dc.contributor.author | Μιχαήλ, Χρήστος Μ. | el |
dc.contributor.author | Βαλαής, Ιωάννης Γ. | el |
dc.contributor.author | Φούντος, Γεώργιος Π. | el |
dc.contributor.author | Καλύβας, Νεκτάριος Ι. | el |
dc.date.accessioned | 2015-02-03T17:45:18Z | |
dc.date.available | 2015-02-03T17:45:18Z | |
dc.date.issued | 2015-02-03 | |
dc.identifier.uri | http://hdl.handle.net/11400/5587 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://e-jst.teiath.gr/ | en |
dc.subject | Nuclear medicine | |
dc.subject | Πυρηνική ιατρική | |
dc.subject | MTF | |
dc.subject | Image degradation | |
dc.subject | Scintillating screen | |
dc.subject | Σπινθηρίζουσα οθόνη | |
dc.subject | Υποβάθμιση εικόνας | |
dc.title | X-ray image degradation passing through thin glass substrate | en |
heal.type | journalArticle | |
heal.generalDescription | Special issue: Workshop on Bio-Medical Instrumentation and related Engineering And Physical Sciences, Technological Educational Institute of Athens, 6 July 2012 | en |
heal.classification | Medicine | |
heal.classification | Medical physics | |
heal.classification | Ιατρική | |
heal.classification | Ιατρική φυσική | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85083001 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Ιατρική φυσική | |
heal.keywordURI | http://id.loc.gov/authorities/subjects/sh85093011 | |
heal.contributorName | Στρωματιά, Φωτεινή | el |
heal.contributorName | Κανδαράκης, Ιωάννης Σ. | el |
heal.contributorName | Παναγιωτάκης, Γεώργιος Σ. | el |
heal.language | en | |
heal.access | free | |
heal.publicationDate | 2012 | |
heal.bibliographicCitation | Seferis, I.E., Michail, C.M., Valais, I.G., Fountos, G.P., Kalyvas, N.I., et al. (2012). X-ray image degradation passing through thin glass substrate. "e-Journal of Science & Technology". [Online] 7(3): 29-31. Available from: http://e-jst.teiath.gr/ | en |
heal.abstract | The degradation of X-ray image passing through thin glass substrate was experimentally investigated in term of modulation transfer function (MTF). The screen was prepared by sedimentation of the powder phosphor (Gd2O2S:Eu) on thin glass substrate with thickness 140 m (Waldemar Knittel- GmbH). The experiment was carried out under X-ray mammographic conditions. The beam quality was 28 kV, 60 mAs, with W/Rh target/filter combination. The screen was coupled to an optical readout device including a CMOS remote RadEye HR photodiode pixel array. Results showed that there is a 40% degradation of the MTF on average, in the whole spatial frequency range, due to the glass substrate. The glass substrate has a low impact on resolution of the image at low frequencies (12% on average, up to 2.7 cy/mm) and a high impact at medium and high frequencies (70% on average). | en |
heal.publisher | Νερατζής, Ηλίας | el |
heal.publisher | Σιανούδης, Ιωάννης | el |
heal.publisher | Βαλαής, Ιωάννης Γ. | el |
heal.publisher | Φούντος, Γεώργιος Π. | el |
heal.journalName | e-Journal of Science & Technology | en |
heal.journalName | e-Περιοδικό Επιστήμης & Τεχνολογίας | el |
heal.journalType | peer-reviewed | |
heal.fullTextAvailability | true |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: