dc.contributor.author | Καραλή, Ευαγγελία | el |
dc.contributor.author | Ασβεστάς, Παντελής Α. | el |
dc.contributor.author | Ματσόπουλος, Γεώργιος Κ. | el |
dc.contributor.author | Νικήτα, Κωνσταντίνα Σ. | el |
dc.date.accessioned | 2015-02-07T18:36:13Z | |
dc.date.issued | 2015-02-07 | |
dc.identifier.uri | http://hdl.handle.net/11400/5815 | |
dc.rights | Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.source | http://www.embec.eu/ | en |
dc.subject | Manual registration | |
dc.subject | Clinical ophthalmology | |
dc.subject | Χειροκίνητη καταχώρηση | |
dc.subject | Κλινική οφθαλμολογία | |
dc.title | Automatic registration schemes applied to retinal images | en |
heal.type | conferenceItem | |
heal.secondaryTitle | an evaluation study | en |
heal.generalDescription | Proceedings of The 3rd European Medical and Biological Engineering Conference – EMBEC’05 | en |
heal.classification | Medicine | |
heal.classification | Biomedical engineering | |
heal.classification | Ιατρική | |
heal.classification | Βιοϊατρική τεχνολογία | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh00006614 | |
heal.classificationURI | http://id.loc.gov/authorities/subjects/sh85014237 | |
heal.classificationURI | **N/A**-Ιατρική | |
heal.classificationURI | **N/A**-Βιοϊατρική τεχνολογία | |
heal.dateAvailable | 10000-01-01 | |
heal.language | en | |
heal.access | forever | |
heal.recordProvider | Τ.Ε.Ι. Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Τμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας Τ.Ε. | el |
heal.publicationDate | 2005 | |
heal.bibliographicCitation | Karali, E., Asvestas, P., Matsopoulos G. and Nikita, K. (2005). Automatic registration schemes applied to retinal images: an evaluation study. In the 3rd European Medical and Biological Engineering Conference-EMBEC’05. Prague, 20th–25th November, 2005. | en |
heal.abstract | In this paper, different automatic registration schemes based on global and local optimization techniques in conjunction with different similarity measures are compared in terms of accuracy and efficiency. Results from every optimization procedure are quantitatively evaluated with respect to the manual registration, which is the standard registration method used in clinical practice. The comparison has shown automatic registration schemes based on CD consist of an accurate and reliable method that can be used in clinical ophthalmology, as a satisfactory alternative to the manual method | en |
heal.publisher | [χ.ό.] | en |
heal.fullTextAvailability | true | |
heal.conferenceName | European Medical and Biological Engineering Conference – EMBEC’05 | en |
heal.conferenceItemType | full paper |
Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο: