Εμφάνιση απλής εγγραφής

dc.contributor.author Srivastav, Rupesh K. en
dc.contributor.author Ahmad, Qazi Shoeb en
dc.contributor.author Khan, Abdul Wadood en
dc.contributor.author Mishra, Alok en
dc.date.accessioned 2015-02-09T20:30:13Z
dc.date.available 2015-02-09T20:30:13Z
dc.date.issued 2015-02-09
dc.identifier.uri http://hdl.handle.net/11400/5948
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://e-jst.teiath.gr/ en
dc.subject Overlapping stenosis
dc.subject Catheter
dc.subject Permeable wall
dc.subject Darcy number
dc.subject Slip parameter
dc.subject Επικάλυψη στένωσης
dc.subject Καθετήρας
dc.subject Διαπερατό τοίχωμα
dc.subject Παράμετρος ολίσθησης
dc.title Blood flow through an overlapping stenosis in catheterized artery with permeable wall en
heal.type journalArticle
heal.classification Medicine
heal.classification Internal medicine
heal.classification Ιατρική
heal.classification Εσωτερική παθολογία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85067347
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Εσωτερική παθολογία
heal.language en
heal.access free
heal.publicationDate 2013
heal.bibliographicCitation Srivastav, R. K., Ahmad, Q. S., Khan, A.W. & Mishra, A. (2013) Blood flow through an overlapping stenosis in catheterized artery with permeable wall. "e-Journal of Science & Technology". [Online] 8(2). p. 43-53. Available from: http://e-jst.teiath.gr/ en
heal.abstract The present paper is concerned with the effect on the flow characteristics of blood due to presence of an overlapping stenosis in an inserted catheterized artery with permeable wall has been investigated. The expressions for the flow characteristics – the flow rate, the impedance (resistance to flow), the wall shear stress in stenotic region, the shear stress at the stenosis two throats and critical height of the stenosis, has been derived. A significant increase in the magnitude of the flow characteristics occurs with respect to flow parameters and catheter size. en
heal.publisher Νερατζής, Ηλίας el
heal.publisher Σιανούδης, Ιωάννης el
heal.journalName e-Journal of Science & Technology en
heal.journalName e-Περιοδικό Επιστήμης & Τεχνολογίας el
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες