Εμφάνιση απλής εγγραφής

dc.contributor.author Lavudu, Petikam en
dc.contributor.author Rani, Avula Prameela en
dc.contributor.author Sekaran, Chandra Bala en
dc.date.accessioned 2015-02-17T07:22:10Z
dc.date.available 2015-02-17T07:22:10Z
dc.date.issued 2015-02-17
dc.identifier.uri http://hdl.handle.net/11400/6399
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://e-jst.teiath.gr/ en
dc.subject Cilazapril
dc.subject Cyano column
dc.subject HPLC analysis
dc.subject Pharmaceutical formulations
dc.subject Σιλαζαπρίλη
dc.subject Φαρμακευτικές συνθέσεις
dc.title Application of high performance liquid chromatography to the analysis of cilazapril in bulk and pharmaceutical formations en
heal.type journalArticle
heal.classification Medicine
heal.classification Pharmacy
heal.classification Ιατρική
heal.classification Φαρμακευτική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85100603
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φαρμακευτική
heal.language en
heal.access free
heal.publicationDate 2014
heal.bibliographicCitation Lavudu, P., Rani, A.P. and Sekaran, C.B. (2014). Application of high performance liquid chromatography to the analysis of cilazapril in bulk and pharmaceutical formations. "e-Journal of Science & Technology". [Online] 9(5): 137-146. Available from: http://e-jst.teiath.gr/ en
heal.abstract A rapid, selective, precise and accurate high-performance liquid chromatography method for the estimation of cilazapril (CZP) in bulk and pharmaceutical formulations has been developed and validated. The assay of the cilazapril was performed on a Cyano Column (150 mm x 4.6 mm, 5 μm particle size) with UV detection at 212 nm. The mobile phase consists of a formate buffer (pH 3.75)-acetonitrile (60:40 v/v) and a flow rate of 1 ml/min was maintained. The calibration curve was linear over the range of 2–200 μg/ml (r 2 = 0.9990). The proposed method was validated as per International Conference on Harmonization guidelines. The proposed method was successfully applied to the quantification of (CZP) in pharmaceutical formulations. The proposed method will be useful for routine quality control analysis of (CZP). en
heal.publisher Νερατζής, Ηλίας el
heal.publisher Σιανούδης, Ιωάννης el
heal.journalName e-Journal of Science & Technology en
heal.journalName e-Περιοδικό Επιστήμης & Τεχνολογίας el
heal.journalType peer-reviewed
heal.fullTextAvailability true