Εμφάνιση απλής εγγραφής

dc.contributor.author Τσίου, Χρυσούλα el
dc.contributor.author Θεοδοσοπούλου, Ελένη el
dc.contributor.author Ευθυμιάτος, Δ. el
dc.contributor.author Νότης, Π. el
dc.contributor.author Κυριάκου, Κ. el
dc.date.accessioned 2015-04-24T20:24:24Z
dc.date.available 2015-04-24T20:24:24Z
dc.date.issued 2015-04-24
dc.identifier.uri http://hdl.handle.net/11400/8894
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://link.springer.com/article/10.1007/s001340050676 en
dc.subject μονάδα εντατικής θεραπείας
dc.subject ηχορύπανση
dc.subject περιβάλλον
dc.subject Ευγενίδειο νοσοκομείο
dc.subject intensive care unit
dc.subject Noise pollution
dc.subject Environment
dc.subject Evgenidion Hospital
dc.title Noise sources and levels in the Evgenidion Hospital intensive care unit el
heal.type journalArticle
heal.classification Ιατρική
heal.classification Νοσηλευτική
heal.classification Medicine
heal.classification Nursing
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Νοσηλευτική
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85093362
heal.keywordURI http://id.loc.gov/authorities/subjects/sh85092188
heal.identifier.secondary DOI: 10.1007/s001340050676
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Επαγγελμάτων Υγείας και Πρόνοιας. Τμήμα Νοσηλευτικής el
heal.publicationDate 1998-08
heal.bibliographicCitation Tsiou, C., Eftymiatos, D., Theodossopoulou, E., Notis, P. and Kiriakou, K. (1998) Noise sources and levels in the Evgenidion Hospital intensive care unit. Intensive Care Medicine. [Online] 24 (8), pp.845-847. Available from: http://link.springer.com [Accessed 24/04/2015] en
heal.abstract Noise sources and levels were evaluated in a six-bed intensive care unit (ICU) in Athens, Greece. Ten patients (six males, four females) completed specifically designed questionnaires, and at the same time nine 8-h sound measuring sessions took place. A Bruel and Kjaer 2231 sound-meter was used on the decibel-A scale combined with observation. Human activity, operating equipment and construction engineering of the hospital building were identified as sources of noise. Noise levels were elevated [LEQ=60.3–67.4 dB(A)]. No reliable information was obtained from the questionnaires. ICU noise levels were higher by 27 dB(A) than recommended hospitals levels. To counteract noise pollution in ICUs, staff awareness and sensitivity are needed. en
heal.journalName Intensive Care Medicine en
heal.journalType peer-reviewed
heal.fullTextAvailability true


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: art%3A10.1007%2Fs001340050676.pdf
    Μέγεθος: 240.7Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες