Εμφάνιση απλής εγγραφής

dc.contributor.author Παπαγιάννη, Π. el
dc.contributor.author Βαρβαρέσου, Αθανασία el
dc.contributor.author Παπαγεωργίου, Σπυρίδων el
dc.contributor.author Παντέρη, Ειρήνη el
dc.date.accessioned 2015-04-28T16:43:41Z
dc.date.available 2015-04-28T16:43:41Z
dc.date.issued 2015-04-28
dc.identifier.uri http://hdl.handle.net/11400/9197
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.source http://www.sciencedirect.com en
dc.subject Καλλυντικά
dc.subject Πειραματικές μέθοδοι
dc.subject Experimental methods
dc.title Development and validation of an ion-pair RP-HPLC method for the determination of oligopeptide-20 in cosmeceuticals en
heal.type journalArticle
heal.classification Aesthetics
heal.classification Chemistry
heal.classification Αισθητική
heal.classification Χημεία
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85001441
heal.classificationURI http://id.loc.gov/authorities/subjects/sh85022986
heal.classificationURI **N/A**-Αισθητική
heal.classificationURI **N/A**-Χημεία
heal.identifier.secondary 10.1016/j.jpba.2011.07.001
heal.language en
heal.access campus
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθηνών. Σχολή Επαγγελμάτων Υγείας και Πρόνοιας. Τμήμα Αισθητικής και Κοσμητολογίας el
heal.publicationDate 2011
heal.bibliographicCitation Papagianni, P., Varvaresou, A., Papageorgiou, S. and Panderi, I. (2011) Development and validation of an ion-pair RP-HPLC method for the determination of oligopeptide-20 in cosmeceuticals. "Journal of Pharmaceutical and Biomedical Analysis", 56 (3), p.645-649 en
heal.abstract Oligopeptide-20 is a growth-factor mimicking peptide used in cosmeceuticals. This article describes the development and validation of an ion-pair reversed-phase liquid chromatography method that allows, after liquid–liquid extraction, the quantification of oligopeptide-20 in cosmetic creams. Chromatographic separation was achieved on a cyanopropyl Hypersil analytical column (100 mm × 2.1 mm i.d., 5 μm particle size), using a mobile phase of acetonitrile–heptafluorobutyric acid (pH = 2.5, 9.0 mM) (70:30, v/v) containing 0.045% diethylamine at a flow rate of 0.50 mL min−1. Ultraviolet (UV) spectrophotometric detection at 225 nm was used. The method had linear calibration curve over the range 1.35–4.95 μg mL−1 for oligopeptide-20. The intra- and inter-day RSD values were less than 3.3%, while the relative percentage error, %Er, was less than 1.9. The developed method was applied successfully to the quality control of a cosmetic cream containing 0.003% (w/w) oligopeptide-20. en
heal.journalName Journal of Pharmaceutical and Biomedical Analysis el
heal.journalType peer-reviewed
heal.fullTextAvailability false


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: 36. Development and validation ...
    Μέγεθος: 322.9Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες