Εμφάνιση απλής εγγραφής

dc.contributor.author Μιχαήλ, Χρήστος Μ. el
dc.contributor.author Δαυίδ, Στράτος el
dc.contributor.author Βαλαής, Ιωάννης Γ. el
dc.contributor.author Τουτουντζής, Ανδριανός el
dc.contributor.author Καλύβας, Νεκτάριος Ι. el
dc.date.accessioned 2015-04-28T17:32:57Z
dc.date.available 2015-04-28T17:32:57Z
dc.date.issued 2015-04-28
dc.identifier.uri http://hdl.handle.net/11400/9201
dc.rights Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Inorganic scintillators
dc.subject Ανόργανοι σπινθηριστές
dc.subject Ανιχνευτές ακτινοβολίας
dc.subject Χαρακτηριστικά απεικόνισης μεταφοράς
dc.subject Radiation detectors
dc.subject Imaging transfer characteristics
dc.title Modeling the imaging trandfer characteristics of LSO powder scintillator for use in x-ray mammography en
heal.type conferenceItem
heal.classification Medicine
heal.classification Ιατρική
heal.classification Φυσική
heal.classification Physics
heal.classificationURI http://id.loc.gov/authorities/subjects/sh00006614
heal.classificationURI **N/A**-Ιατρική
heal.classificationURI **N/A**-Φυσική
heal.classificationURI http://skos.um.es/unescothes/C02994
heal.keywordURI http://id.loc.gov/authorities/subjects/sh96012193
heal.contributorName Παναγιωτάκης, Γιώργος Σ. el
heal.contributorName Κανδαράκης, Ιωάννης el
heal.language en
heal.access free
heal.recordProvider Τεχνολογικό Εκπαιδευτικό Ίδρυμα Αθήνας. Σχολή Τεχνολογικών Εφαρμογών. Tμήμα Μηχανικών Βιοϊατρικής Τεχνολογίας T.E. el
heal.publicationDate 2007-07
heal.bibliographicCitation Michail, C., David, S., Toutountzis, A., Kalivas, N., Kandarakis, I. e.t. (2007) Modeling the imaging trandfer characteristics of LSO powder scintillator for use in x-ray mammography. In 2nd International conference on experiments/process/system modeling/simulation & optimization. Athens, Greece, 4-7 July 2007. pp.1-2. en
heal.abstract The aim of the present study was to model the imaging transfer characteristics of Lu2SiO5:Ce (LSO:Ce) powder scintillator for use in X-ray mammography detectors. LSO:Ce scintillator is a high efficiency and fast emitting material. An LSO:Ce powder scintillating screen, with a coating thickness of 25 mg / cm2 , was prepared in our laboratory. The imaging performance of the screen was assessed by experimental determination of the modulation transfer function (MTF) and the detective quantum efficiency (DQE). An MTF mathematical relation derived by the theoretical model was fitted to experimental MTF values in order to estimate the light attenuation properties of the scintillator. Screen irradiation was performed under exposure conditions employed in mammographic applications (27 kVp, 63 mAs). MTF was determined by the square wave response function (SWRF) method whereas DQE was estimated by using: (a) the MTF curve, (b) the noise transfer function (NTF) and (c) K.E.R.M.A. measurements, according to IEC standard 62220-1. Results showed that LSO:Ce exhibits high MTF, which is comparable to that of the commercially used Gd2O2S: Tb powder scintillator. Considering our MTF results and the fast response of LSO:Ce scintillator screen (40 ns), this material can be considered for use in X-ray mammographic detectors. en
heal.fullTextAvailability true
heal.conferenceName 2nd International conference on experiments/process/system modeling/simulation & optimization en
heal.conferenceItemType short paper


Αρχεία σε αυτό το τεκμήριο

  • Όνομα: Modeling the imaging transfer.pdf
    Μέγεθος: 70.60Kb
    Μορφότυπο: PDF

Οι παρακάτω άδειες σχετίζονται με αυτό το τεκμήριο:

Εμφάνιση απλής εγγραφής

Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες Εκτός από όπου ορίζεται κάτι διαφορετικό, αυτή η άδεια περιγράφεται ως Αναφορά Δημιουργού-Μη Εμπορική Χρήση-Όχι Παράγωγα Έργα 3.0 Ηνωμένες Πολιτείες